虚拟三次谐波反电动势在无刷直流电机驱动中识别错位霍尔效应位置传感器中的评估

Dimitrios A. Papathanasopoulos, E. Mitronikas
{"title":"虚拟三次谐波反电动势在无刷直流电机驱动中识别错位霍尔效应位置传感器中的评估","authors":"Dimitrios A. Papathanasopoulos, E. Mitronikas","doi":"10.1109/DEMPED.2019.8864851","DOIUrl":null,"url":null,"abstract":"In this study, a robust fault diagnostic technique, based on the virtual third harmonic Back-EMF, is proposed to identify the Hall-effect position sensor misalignment in Brushless DC (BLDC) motor drives. The proposed technique can also be exploited in sensorless BLDC drives to highlight the commutation errors and, consequently, the unbalanced operation of a BLDC motor drive, either sensor-based or not, can be detected. Therefore, potential signals, which incorporate the virtual third harmonic Back-EMF, are investigated in the frequency domain for a reliable diagnosis of the defective system. Through the comparison of the pros and cons of each signal, the voltage difference between the neutral point of a resistor network and the half of the DC-link is proposed for the development of the diagnostic technique. Thus, this signal is evaluated in identifying both the unbalanced system operation and the severity of the defect in a wide speed and load range.","PeriodicalId":397001,"journal":{"name":"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Evaluation of the Virtual Third Harmonic Back-EMF in Identifying Misaligned Hall-effect Position Sensors in Brushless DC Motor Drives\",\"authors\":\"Dimitrios A. Papathanasopoulos, E. Mitronikas\",\"doi\":\"10.1109/DEMPED.2019.8864851\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a robust fault diagnostic technique, based on the virtual third harmonic Back-EMF, is proposed to identify the Hall-effect position sensor misalignment in Brushless DC (BLDC) motor drives. The proposed technique can also be exploited in sensorless BLDC drives to highlight the commutation errors and, consequently, the unbalanced operation of a BLDC motor drive, either sensor-based or not, can be detected. Therefore, potential signals, which incorporate the virtual third harmonic Back-EMF, are investigated in the frequency domain for a reliable diagnosis of the defective system. Through the comparison of the pros and cons of each signal, the voltage difference between the neutral point of a resistor network and the half of the DC-link is proposed for the development of the diagnostic technique. Thus, this signal is evaluated in identifying both the unbalanced system operation and the severity of the defect in a wide speed and load range.\",\"PeriodicalId\":397001,\"journal\":{\"name\":\"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2019.8864851\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2019.8864851","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种基于虚拟三次谐波反电动势的鲁棒故障诊断技术,用于识别无刷直流(BLDC)电机驱动中的霍尔效应位置传感器错位。所提出的技术也可以在无传感器无刷直流驱动中利用,以突出换相误差,因此,可以检测到基于或不基于传感器的无刷直流电机驱动的不平衡运行。因此,在频域研究包含虚拟三次谐波反电动势的电位信号,以便对故障系统进行可靠的诊断。通过对各信号优缺点的比较,提出了电阻器网络中性点与直流链路半段之间的电压差,为诊断技术的发展提供依据。因此,该信号在确定不平衡系统运行和在宽速度和负载范围内缺陷的严重性时进行评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the Virtual Third Harmonic Back-EMF in Identifying Misaligned Hall-effect Position Sensors in Brushless DC Motor Drives
In this study, a robust fault diagnostic technique, based on the virtual third harmonic Back-EMF, is proposed to identify the Hall-effect position sensor misalignment in Brushless DC (BLDC) motor drives. The proposed technique can also be exploited in sensorless BLDC drives to highlight the commutation errors and, consequently, the unbalanced operation of a BLDC motor drive, either sensor-based or not, can be detected. Therefore, potential signals, which incorporate the virtual third harmonic Back-EMF, are investigated in the frequency domain for a reliable diagnosis of the defective system. Through the comparison of the pros and cons of each signal, the voltage difference between the neutral point of a resistor network and the half of the DC-link is proposed for the development of the diagnostic technique. Thus, this signal is evaluated in identifying both the unbalanced system operation and the severity of the defect in a wide speed and load range.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信