G. Domański, B. Konarzewski, R. Kurjata, K. Zaremba, J. Marzec, M. Dziewiecki, M. Ziembicki, A. Rychter, W. Smolik, Roman Szabatin, P. Brzeski
{"title":"双源法测量死区时间——测量时间划分的优化","authors":"G. Domański, B. Konarzewski, R. Kurjata, K. Zaremba, J. Marzec, M. Dziewiecki, M. Ziembicki, A. Rychter, W. Smolik, Roman Szabatin, P. Brzeski","doi":"10.5604/01.3001.0011.6007","DOIUrl":null,"url":null,"abstract":"The article presents the analysis of the dead time measurement using two sources for a non-paralyzable detector. It determined the optimum division of count rate measurement time between both source measurement and a single source one. Results of the work can be used to optimize dead time measurement for systems which count photons or particles.","PeriodicalId":142227,"journal":{"name":"Informatics, Control, Measurement in Economy and Environment Protection","volume":" 23","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dead time measurement by two-source method – optimization of measurement time division\",\"authors\":\"G. Domański, B. Konarzewski, R. Kurjata, K. Zaremba, J. Marzec, M. Dziewiecki, M. Ziembicki, A. Rychter, W. Smolik, Roman Szabatin, P. Brzeski\",\"doi\":\"10.5604/01.3001.0011.6007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article presents the analysis of the dead time measurement using two sources for a non-paralyzable detector. It determined the optimum division of count rate measurement time between both source measurement and a single source one. Results of the work can be used to optimize dead time measurement for systems which count photons or particles.\",\"PeriodicalId\":142227,\"journal\":{\"name\":\"Informatics, Control, Measurement in Economy and Environment Protection\",\"volume\":\" 23\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Informatics, Control, Measurement in Economy and Environment Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0011.6007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Informatics, Control, Measurement in Economy and Environment Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0011.6007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dead time measurement by two-source method – optimization of measurement time division
The article presents the analysis of the dead time measurement using two sources for a non-paralyzable detector. It determined the optimum division of count rate measurement time between both source measurement and a single source one. Results of the work can be used to optimize dead time measurement for systems which count photons or particles.