{"title":"零电压烧制,变压器耦合可控硅功率控制应用于浮法玻璃工艺中锡浴温度控制","authors":"L. Heath, R. C. Blackmond","doi":"10.1109/IAS.1989.96823","DOIUrl":null,"url":null,"abstract":"A novel thyristor-based power circuit is described which substitutes zero-voltage fired, time proportioning control, and thus allows fewer transformer taps while causing no degradation of circuit power factor. In addition, harmonic distortion usually associated with phase angle control in this application is also eliminated. A system description outlining power requirements, a comparison of power factor costs, and system design philosophy is provided, along with some operational history and an explanation of the thyristor control.<<ETX>>","PeriodicalId":274766,"journal":{"name":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","volume":"162 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Zero voltage fired, transformer coupled thyristor power control applied for temperature control of the tin bath in the float glass process\",\"authors\":\"L. Heath, R. C. Blackmond\",\"doi\":\"10.1109/IAS.1989.96823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel thyristor-based power circuit is described which substitutes zero-voltage fired, time proportioning control, and thus allows fewer transformer taps while causing no degradation of circuit power factor. In addition, harmonic distortion usually associated with phase angle control in this application is also eliminated. A system description outlining power requirements, a comparison of power factor costs, and system design philosophy is provided, along with some operational history and an explanation of the thyristor control.<<ETX>>\",\"PeriodicalId\":274766,\"journal\":{\"name\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"162 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1989.96823\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1989.96823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Zero voltage fired, transformer coupled thyristor power control applied for temperature control of the tin bath in the float glass process
A novel thyristor-based power circuit is described which substitutes zero-voltage fired, time proportioning control, and thus allows fewer transformer taps while causing no degradation of circuit power factor. In addition, harmonic distortion usually associated with phase angle control in this application is also eliminated. A system description outlining power requirements, a comparison of power factor costs, and system design philosophy is provided, along with some operational history and an explanation of the thyristor control.<>