真空灭流器各电极断流后绝缘恢复特性

T. Matsuo, H. Fujimori, D. Hara, S. Yanabu, Hiroki Icbikawa, Y. Matsui, M. Sakaki
{"title":"真空灭流器各电极断流后绝缘恢复特性","authors":"T. Matsuo, H. Fujimori, D. Hara, S. Yanabu, Hiroki Icbikawa, Y. Matsui, M. Sakaki","doi":"10.1109/DEIV.2004.1422613","DOIUrl":null,"url":null,"abstract":"The insulation recovery characteristic after current interruption for vacuum interrupter was investigated. We used spiral electrode and axial magnetic field electrode for comparison of structure, CuBi contact and CuCr contact were used for comparison of contact material. In this paper, we discussed reasons of different characteristics for each electrode.","PeriodicalId":137370,"journal":{"name":"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Insulation recovery characteristics after current interruption for various electrodes of vacuum interrupter\",\"authors\":\"T. Matsuo, H. Fujimori, D. Hara, S. Yanabu, Hiroki Icbikawa, Y. Matsui, M. Sakaki\",\"doi\":\"10.1109/DEIV.2004.1422613\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The insulation recovery characteristic after current interruption for vacuum interrupter was investigated. We used spiral electrode and axial magnetic field electrode for comparison of structure, CuBi contact and CuCr contact were used for comparison of contact material. In this paper, we discussed reasons of different characteristics for each electrode.\",\"PeriodicalId\":137370,\"journal\":{\"name\":\"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEIV.2004.1422613\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2004.1422613","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

研究了真空灭流器断流后的绝缘恢复特性。我们采用螺旋电极和轴向磁场电极进行结构比较,采用CuBi触点和CuCr触点进行触点材料比较。本文讨论了各电极特性不同的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Insulation recovery characteristics after current interruption for various electrodes of vacuum interrupter
The insulation recovery characteristic after current interruption for vacuum interrupter was investigated. We used spiral electrode and axial magnetic field electrode for comparison of structure, CuBi contact and CuCr contact were used for comparison of contact material. In this paper, we discussed reasons of different characteristics for each electrode.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信