{"title":"基于同步旋转角度的改进p-q无功电流检测方法研究","authors":"X. Zhou, Weibao Zhong, Youjie Ma, Kairui Guo","doi":"10.1109/ICMA52036.2021.9512597","DOIUrl":null,"url":null,"abstract":"Based on the analysis of the reactive current detection method based on the instantaneous power theory, a voltage detection method based on the synchronous rotary angle is proposed. At the same time, the voltage detection method is introduced into the traditional p-q detection method to form an improved p-q reactive current detection method based on the synchronous rotary angle. This method realizes the accurate detection of reactive current when the three-phase grid voltage is unbalanced or contains harmonics. The Matlab/Simulink simulation verification proves that the method has high detection accuracy, good dynamic performance, and can meet the requirements of reactive power compensation current detection.","PeriodicalId":339025,"journal":{"name":"2021 IEEE International Conference on Mechatronics and Automation (ICMA)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on Improved p-q Reactive Current Detection Method Based on Synchronous Rotary Angle\",\"authors\":\"X. Zhou, Weibao Zhong, Youjie Ma, Kairui Guo\",\"doi\":\"10.1109/ICMA52036.2021.9512597\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the analysis of the reactive current detection method based on the instantaneous power theory, a voltage detection method based on the synchronous rotary angle is proposed. At the same time, the voltage detection method is introduced into the traditional p-q detection method to form an improved p-q reactive current detection method based on the synchronous rotary angle. This method realizes the accurate detection of reactive current when the three-phase grid voltage is unbalanced or contains harmonics. The Matlab/Simulink simulation verification proves that the method has high detection accuracy, good dynamic performance, and can meet the requirements of reactive power compensation current detection.\",\"PeriodicalId\":339025,\"journal\":{\"name\":\"2021 IEEE International Conference on Mechatronics and Automation (ICMA)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Conference on Mechatronics and Automation (ICMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMA52036.2021.9512597\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on Mechatronics and Automation (ICMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMA52036.2021.9512597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Improved p-q Reactive Current Detection Method Based on Synchronous Rotary Angle
Based on the analysis of the reactive current detection method based on the instantaneous power theory, a voltage detection method based on the synchronous rotary angle is proposed. At the same time, the voltage detection method is introduced into the traditional p-q detection method to form an improved p-q reactive current detection method based on the synchronous rotary angle. This method realizes the accurate detection of reactive current when the three-phase grid voltage is unbalanced or contains harmonics. The Matlab/Simulink simulation verification proves that the method has high detection accuracy, good dynamic performance, and can meet the requirements of reactive power compensation current detection.