G. Brusco, A. Burgio, D. Menniti, M. Motta, A. Pinnarelli, N. Sorrentino
{"title":"单相并联有源电力滤波器谐波电压补偿的重复控制","authors":"G. Brusco, A. Burgio, D. Menniti, M. Motta, A. Pinnarelli, N. Sorrentino","doi":"10.1109/EEEIC.2016.7555478","DOIUrl":null,"url":null,"abstract":"This paper is focused on a single phase shunt active filter based on detection of harmonic voltages at the point of installation; the mission of the active filter is to eliminate these harmonic voltages implementing a repetitive-based control. The active filter is a single-phase voltage-controlled voltage source inverter controlled so to generate a harmonic voltage in phase with the one detected at the point of installation. The proposed repetitive-based control regulates the power at the fundamental frequency so to maintaining the dc voltage of the capacitor placed on the dc side of the filter close to a reference; such an issue is faced implementing the self-charging functionality or supplying real power to the grid when the active filter is a distributed generation solution. Numerical results are provided so to demonstrate the effectiveness and the feasibility of the proposed repetitive-based control in compensating harmonic voltages in an electrical power distribution system.","PeriodicalId":246856,"journal":{"name":"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A repetitive-based control for a single-phase shunt active power filter for harmonic voltage compensation\",\"authors\":\"G. Brusco, A. Burgio, D. Menniti, M. Motta, A. Pinnarelli, N. Sorrentino\",\"doi\":\"10.1109/EEEIC.2016.7555478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper is focused on a single phase shunt active filter based on detection of harmonic voltages at the point of installation; the mission of the active filter is to eliminate these harmonic voltages implementing a repetitive-based control. The active filter is a single-phase voltage-controlled voltage source inverter controlled so to generate a harmonic voltage in phase with the one detected at the point of installation. The proposed repetitive-based control regulates the power at the fundamental frequency so to maintaining the dc voltage of the capacitor placed on the dc side of the filter close to a reference; such an issue is faced implementing the self-charging functionality or supplying real power to the grid when the active filter is a distributed generation solution. Numerical results are provided so to demonstrate the effectiveness and the feasibility of the proposed repetitive-based control in compensating harmonic voltages in an electrical power distribution system.\",\"PeriodicalId\":246856,\"journal\":{\"name\":\"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2016.7555478\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2016.7555478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A repetitive-based control for a single-phase shunt active power filter for harmonic voltage compensation
This paper is focused on a single phase shunt active filter based on detection of harmonic voltages at the point of installation; the mission of the active filter is to eliminate these harmonic voltages implementing a repetitive-based control. The active filter is a single-phase voltage-controlled voltage source inverter controlled so to generate a harmonic voltage in phase with the one detected at the point of installation. The proposed repetitive-based control regulates the power at the fundamental frequency so to maintaining the dc voltage of the capacitor placed on the dc side of the filter close to a reference; such an issue is faced implementing the self-charging functionality or supplying real power to the grid when the active filter is a distributed generation solution. Numerical results are provided so to demonstrate the effectiveness and the feasibility of the proposed repetitive-based control in compensating harmonic voltages in an electrical power distribution system.