{"title":"Delta 1 TT和改良TT系统在复合体和髋臼翻修术后的5年生存率","authors":"Dirk P Hogerzeil","doi":"10.52768/2691-7785/1080","DOIUrl":null,"url":null,"abstract":"Introduction: Use of Trabecular Titanium cups in total hip arthroplasty is expected to reduce the incidence of loosening of the acetabular component of the prosthesis. We reviewed clinical outcomes of the Delta One TT and Delta Revision TT acetabular systems during five-year follow-up after primary complex or acetabular revision surgery.","PeriodicalId":396724,"journal":{"name":"Journal on Surgery","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Five-Year Survival of the Delta One TT and Revision TT Systems after Primary Complex and Acetabular Revision Surgery\",\"authors\":\"Dirk P Hogerzeil\",\"doi\":\"10.52768/2691-7785/1080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Use of Trabecular Titanium cups in total hip arthroplasty is expected to reduce the incidence of loosening of the acetabular component of the prosthesis. We reviewed clinical outcomes of the Delta One TT and Delta Revision TT acetabular systems during five-year follow-up after primary complex or acetabular revision surgery.\",\"PeriodicalId\":396724,\"journal\":{\"name\":\"Journal on Surgery\",\"volume\":\"130 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal on Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52768/2691-7785/1080\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal on Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52768/2691-7785/1080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
简介:全髋关节置换术中使用小梁钛杯有望减少假体髋臼部分松动的发生率。我们回顾了Delta One TT和Delta Revision TT髋臼系统在初次复杂或髋臼翻修手术后5年随访期间的临床结果。
Five-Year Survival of the Delta One TT and Revision TT Systems after Primary Complex and Acetabular Revision Surgery
Introduction: Use of Trabecular Titanium cups in total hip arthroplasty is expected to reduce the incidence of loosening of the acetabular component of the prosthesis. We reviewed clinical outcomes of the Delta One TT and Delta Revision TT acetabular systems during five-year follow-up after primary complex or acetabular revision surgery.