[尿中二硫化碳排泄——工作场所和环境浓度范围的生物暴露试验]。

H Winkelmann, J Prösch, W Engewald, K Horn
{"title":"[尿中二硫化碳排泄——工作场所和环境浓度范围的生物暴露试验]。","authors":"H Winkelmann,&nbsp;J Prösch,&nbsp;W Engewald,&nbsp;K Horn","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The biological control procedure for carbon disulphide (CS2), the determination of free and bound CS2 in urine--a procedure already applied to hygienic surveillance--were modified by using gas chromatography and sulphide selective detection (FPD). The results obtained by the changed biological monitoring test in workplace and environmental surveillance are present and discussed. For CS2 concentrations at workplaces in the range of 8-54 mg/m3 a correlation coefficient of r = 0.56 (n = 11, p less than 0.07) was calculated for the mathematical connection of CS2 shift exposure and CS2 content in urine. For environmental exposures in the range of the CS2 immision short term threshold value (MIKK) of 0.03 mg/m3 the procedure may discriminate significantly exposure load from naturally occurring CS2 background.</p>","PeriodicalId":76839,"journal":{"name":"Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete","volume":"37 3","pages":"102-4"},"PeriodicalIF":0.0000,"publicationDate":"1991-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Carbon disulfide excretion in urine--a biological exposure test for the workplace and environmental concentration ranges].\",\"authors\":\"H Winkelmann,&nbsp;J Prösch,&nbsp;W Engewald,&nbsp;K Horn\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The biological control procedure for carbon disulphide (CS2), the determination of free and bound CS2 in urine--a procedure already applied to hygienic surveillance--were modified by using gas chromatography and sulphide selective detection (FPD). The results obtained by the changed biological monitoring test in workplace and environmental surveillance are present and discussed. For CS2 concentrations at workplaces in the range of 8-54 mg/m3 a correlation coefficient of r = 0.56 (n = 11, p less than 0.07) was calculated for the mathematical connection of CS2 shift exposure and CS2 content in urine. For environmental exposures in the range of the CS2 immision short term threshold value (MIKK) of 0.03 mg/m3 the procedure may discriminate significantly exposure load from naturally occurring CS2 background.</p>\",\"PeriodicalId\":76839,\"journal\":{\"name\":\"Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete\",\"volume\":\"37 3\",\"pages\":\"102-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur die gesamte Hygiene und ihre Grenzgebiete","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

二硫化碳(CS2)的生物控制程序,尿液中游离和结合CS2的测定-已经应用于卫生监测的程序-通过使用气相色谱法和硫化物选择性检测(FPD)进行了修改。介绍并讨论了在工作场所和环境监测中进行生物监测试验的结果。对于工作场所CS2浓度在8-54 mg/m3范围内,计算出CS2位移暴露与尿液中CS2含量的数学联系的相关系数r = 0.56 (n = 11, p小于0.07)。对于处于CS2排放短期阈值(MIKK) 0.03 mg/m3范围内的环境暴露,该程序可以显著区分暴露负荷与自然发生的CS2背景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Carbon disulfide excretion in urine--a biological exposure test for the workplace and environmental concentration ranges].

The biological control procedure for carbon disulphide (CS2), the determination of free and bound CS2 in urine--a procedure already applied to hygienic surveillance--were modified by using gas chromatography and sulphide selective detection (FPD). The results obtained by the changed biological monitoring test in workplace and environmental surveillance are present and discussed. For CS2 concentrations at workplaces in the range of 8-54 mg/m3 a correlation coefficient of r = 0.56 (n = 11, p less than 0.07) was calculated for the mathematical connection of CS2 shift exposure and CS2 content in urine. For environmental exposures in the range of the CS2 immision short term threshold value (MIKK) of 0.03 mg/m3 the procedure may discriminate significantly exposure load from naturally occurring CS2 background.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信