{"title":"井道与建筑物连接强度的安全性分析","authors":"Xue Ji’ai, Chang Xiaoqing, Tong Yaoting, Ren Lixin","doi":"10.1109/icedme50972.2020.00148","DOIUrl":null,"url":null,"abstract":"There have a great number of existing residential buildings in china that do not have elevators installed, which plagued the lives of aged residents living in for apparent inconvenience. The installation of elevators in these buildings comes into being under this circumstances. In this paper, the hoistway and the building were considered as a whole, and a three-span single safety under the coupling of safety clamp-rail- building was established. The deformation of the guide rail and the force of the supporting point were calculated by three-span guide rail model, when the safety clamp was in motion. It provided a theoretical basis for the calculation of the force and the safety analysis of the elevator steel structure hoistway.","PeriodicalId":155375,"journal":{"name":"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safety analysis of connection strength of the hoistway and the building\",\"authors\":\"Xue Ji’ai, Chang Xiaoqing, Tong Yaoting, Ren Lixin\",\"doi\":\"10.1109/icedme50972.2020.00148\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There have a great number of existing residential buildings in china that do not have elevators installed, which plagued the lives of aged residents living in for apparent inconvenience. The installation of elevators in these buildings comes into being under this circumstances. In this paper, the hoistway and the building were considered as a whole, and a three-span single safety under the coupling of safety clamp-rail- building was established. The deformation of the guide rail and the force of the supporting point were calculated by three-span guide rail model, when the safety clamp was in motion. It provided a theoretical basis for the calculation of the force and the safety analysis of the elevator steel structure hoistway.\",\"PeriodicalId\":155375,\"journal\":{\"name\":\"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)\",\"volume\":\"63 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/icedme50972.2020.00148\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icedme50972.2020.00148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Safety analysis of connection strength of the hoistway and the building
There have a great number of existing residential buildings in china that do not have elevators installed, which plagued the lives of aged residents living in for apparent inconvenience. The installation of elevators in these buildings comes into being under this circumstances. In this paper, the hoistway and the building were considered as a whole, and a three-span single safety under the coupling of safety clamp-rail- building was established. The deformation of the guide rail and the force of the supporting point were calculated by three-span guide rail model, when the safety clamp was in motion. It provided a theoretical basis for the calculation of the force and the safety analysis of the elevator steel structure hoistway.