Muhoroni 60MW燃气轮机电厂性能分析与评价

Moses Jeremiah Barasa Kabeyi, O. Olanrewaju
{"title":"Muhoroni 60MW燃气轮机电厂性能分析与评价","authors":"Moses Jeremiah Barasa Kabeyi, O. Olanrewaju","doi":"10.1109/ICECCME52200.2021.9591134","DOIUrl":null,"url":null,"abstract":"This study was a performance analysis with the aim of improving the performance of an operating gas turbine at Muhoroni, Kenya. Data was collected by observation, questionnaire, interview, and document analysis and used for performance analysis and review. The analysis of the power plant performance indicators showed that plant utilization is low with low load factor and hence low generation from the power plant because of high costs of generation and hence low demand which is limited to peak power supply. The powerplant has two operating gas turbines with recoverable exhaust heat energy of 119.4 MWthermal. The study recommends installation of a 20 MW Rankine cycle steam turbine with exhaust heat boiler for generation of steam. Recovery and applications for the hot cooling air are recommended is also recommended.","PeriodicalId":102785,"journal":{"name":"2021 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Performance Analysis and Evaluation of Muhoroni 60MW Gas Turbine Power Plant\",\"authors\":\"Moses Jeremiah Barasa Kabeyi, O. Olanrewaju\",\"doi\":\"10.1109/ICECCME52200.2021.9591134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study was a performance analysis with the aim of improving the performance of an operating gas turbine at Muhoroni, Kenya. Data was collected by observation, questionnaire, interview, and document analysis and used for performance analysis and review. The analysis of the power plant performance indicators showed that plant utilization is low with low load factor and hence low generation from the power plant because of high costs of generation and hence low demand which is limited to peak power supply. The powerplant has two operating gas turbines with recoverable exhaust heat energy of 119.4 MWthermal. The study recommends installation of a 20 MW Rankine cycle steam turbine with exhaust heat boiler for generation of steam. Recovery and applications for the hot cooling air are recommended is also recommended.\",\"PeriodicalId\":102785,\"journal\":{\"name\":\"2021 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECCME52200.2021.9591134\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECCME52200.2021.9591134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

这项研究是一项性能分析,目的是改善肯尼亚Muhoroni运行中的燃气轮机的性能。采用观察、问卷调查、访谈、文献分析等方法收集数据,并进行绩效分析和评审。对电厂性能指标的分析表明,电厂利用率低,负荷系数低,发电成本高,需求低,仅限峰值供电,因此电厂发电量低。该发电厂有两台运行中的燃气轮机,可回收的余热能量为119.4兆瓦热。该研究建议安装一台20兆瓦的朗肯循环汽轮机和废热锅炉来产生蒸汽。还建议对热冷却空气进行回收和应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Analysis and Evaluation of Muhoroni 60MW Gas Turbine Power Plant
This study was a performance analysis with the aim of improving the performance of an operating gas turbine at Muhoroni, Kenya. Data was collected by observation, questionnaire, interview, and document analysis and used for performance analysis and review. The analysis of the power plant performance indicators showed that plant utilization is low with low load factor and hence low generation from the power plant because of high costs of generation and hence low demand which is limited to peak power supply. The powerplant has two operating gas turbines with recoverable exhaust heat energy of 119.4 MWthermal. The study recommends installation of a 20 MW Rankine cycle steam turbine with exhaust heat boiler for generation of steam. Recovery and applications for the hot cooling air are recommended is also recommended.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信