{"title":"双等离子体冷阴极连续放电试验","authors":"A. Kolomiets, B. Kondratiev, V. I. Turchin","doi":"10.1109/PAC.1997.752748","DOIUrl":null,"url":null,"abstract":"A pulse duoplasmatron with a cold cathode used at preinjectors of the ITEP proton linacs has been tested for generation of a dc proton beam. The operation of the duoplasmatron was studied experimentally with low currents of the discharge. The test bench experiments allowed to modify construction of a pulsed ion source for stable dc operation with a high lifetime. The ion source generated a dc beam of protons with a current /spl ap/12 mA at 30 kV.","PeriodicalId":122662,"journal":{"name":"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Test of duoplasmatron with cold cathode for cw operation\",\"authors\":\"A. Kolomiets, B. Kondratiev, V. I. Turchin\",\"doi\":\"10.1109/PAC.1997.752748\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A pulse duoplasmatron with a cold cathode used at preinjectors of the ITEP proton linacs has been tested for generation of a dc proton beam. The operation of the duoplasmatron was studied experimentally with low currents of the discharge. The test bench experiments allowed to modify construction of a pulsed ion source for stable dc operation with a high lifetime. The ion source generated a dc beam of protons with a current /spl ap/12 mA at 30 kV.\",\"PeriodicalId\":122662,\"journal\":{\"name\":\"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAC.1997.752748\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1997.752748","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Test of duoplasmatron with cold cathode for cw operation
A pulse duoplasmatron with a cold cathode used at preinjectors of the ITEP proton linacs has been tested for generation of a dc proton beam. The operation of the duoplasmatron was studied experimentally with low currents of the discharge. The test bench experiments allowed to modify construction of a pulsed ion source for stable dc operation with a high lifetime. The ion source generated a dc beam of protons with a current /spl ap/12 mA at 30 kV.