{"title":"带扫频控制的DVR可缓解配电系统三相故障时的电压跌落","authors":"P. Poornima, N. Veerappan, R. Sathyanarayanan","doi":"10.1109/ICETEEEM.2012.6494452","DOIUrl":null,"url":null,"abstract":"The point of common coupling voltage during sag condition resulting due to a fault occurring on the parallel feeder in a distribution system evidently shows good dynamic response of the DVR achieved through the sweep mode control. It can also be observed that usage of sweep mode control to DVR eliminates the additional sag detection and makes the DVR multifunctional, such as the same control can be used to compensate any variation in the supply voltage.","PeriodicalId":213443,"journal":{"name":"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)","volume":"165 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"DVR with sweep mode control to alleviate voltage sags on a distribution system for three phase fault\",\"authors\":\"P. Poornima, N. Veerappan, R. Sathyanarayanan\",\"doi\":\"10.1109/ICETEEEM.2012.6494452\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The point of common coupling voltage during sag condition resulting due to a fault occurring on the parallel feeder in a distribution system evidently shows good dynamic response of the DVR achieved through the sweep mode control. It can also be observed that usage of sweep mode control to DVR eliminates the additional sag detection and makes the DVR multifunctional, such as the same control can be used to compensate any variation in the supply voltage.\",\"PeriodicalId\":213443,\"journal\":{\"name\":\"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)\",\"volume\":\"165 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICETEEEM.2012.6494452\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETEEEM.2012.6494452","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
DVR with sweep mode control to alleviate voltage sags on a distribution system for three phase fault
The point of common coupling voltage during sag condition resulting due to a fault occurring on the parallel feeder in a distribution system evidently shows good dynamic response of the DVR achieved through the sweep mode control. It can also be observed that usage of sweep mode control to DVR eliminates the additional sag detection and makes the DVR multifunctional, such as the same control can be used to compensate any variation in the supply voltage.