相量测量单元的最佳位置:文献回顾

N. Manousakis, G. Korres, P. Georgilakis
{"title":"相量测量单元的最佳位置:文献回顾","authors":"N. Manousakis, G. Korres, P. Georgilakis","doi":"10.1109/ISAP.2011.6082183","DOIUrl":null,"url":null,"abstract":"The increasing availability of phasor measurement units (PMUs) at substations enables the synchronized measurements to various applications, such as the monitoring of system state under normal operations or the protection and control of power systems during abnormal operation. The objective of the optimal PMU placement (OPP) problem is to determine a minimal set of PMUs such that the whole system is observable. To solve the OPP problem, mathematical programming, heuristic, and meta-heuristic optimization techniques, have been proposed. This paper provides a comprehensive literature review on the OPP problem and the solution methodologies. Due to the vast number of publications in this field, the most representative papers are reviewed.","PeriodicalId":424662,"journal":{"name":"2011 16th International Conference on Intelligent System Applications to Power Systems","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"67","resultStr":"{\"title\":\"Optimal placement of phasor measurement units: A literature review\",\"authors\":\"N. Manousakis, G. Korres, P. Georgilakis\",\"doi\":\"10.1109/ISAP.2011.6082183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The increasing availability of phasor measurement units (PMUs) at substations enables the synchronized measurements to various applications, such as the monitoring of system state under normal operations or the protection and control of power systems during abnormal operation. The objective of the optimal PMU placement (OPP) problem is to determine a minimal set of PMUs such that the whole system is observable. To solve the OPP problem, mathematical programming, heuristic, and meta-heuristic optimization techniques, have been proposed. This paper provides a comprehensive literature review on the OPP problem and the solution methodologies. Due to the vast number of publications in this field, the most representative papers are reviewed.\",\"PeriodicalId\":424662,\"journal\":{\"name\":\"2011 16th International Conference on Intelligent System Applications to Power Systems\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"67\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 16th International Conference on Intelligent System Applications to Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAP.2011.6082183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 16th International Conference on Intelligent System Applications to Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAP.2011.6082183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 67

摘要

变电站中相量测量单元(pmu)的可用性越来越高,可以对各种应用进行同步测量,例如正常运行时的系统状态监测或异常运行时的电力系统保护和控制。最优PMU配置(OPP)问题的目标是确定PMU的最小集合,使整个系统是可观察的。为了解决OPP问题,提出了数学规划、启发式和元启发式优化技术。本文对OPP问题及其解决方法进行了全面的文献综述。由于这一领域的出版物数量庞大,因此本文对最具代表性的论文进行了综述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal placement of phasor measurement units: A literature review
The increasing availability of phasor measurement units (PMUs) at substations enables the synchronized measurements to various applications, such as the monitoring of system state under normal operations or the protection and control of power systems during abnormal operation. The objective of the optimal PMU placement (OPP) problem is to determine a minimal set of PMUs such that the whole system is observable. To solve the OPP problem, mathematical programming, heuristic, and meta-heuristic optimization techniques, have been proposed. This paper provides a comprehensive literature review on the OPP problem and the solution methodologies. Due to the vast number of publications in this field, the most representative papers are reviewed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信