{"title":"基于AM/FM/GIS系统的TLM应用程序设计","authors":"T. Chen, Jeng-Tyan Cherng","doi":"10.1109/PICA.1997.599424","DOIUrl":null,"url":null,"abstract":"This paper introduces the design of a transformer load management (TLM) application program based on an automated mapping/facilities management/geographic information system (AM/FM/GIS). The data required for this application is mainly extracted from the databases of the AM/FM/GIS system and customer information system (CIS) and combined with customer daily load patterns obtained by load surveys over a long-term period. This integration environment including graphic and nongraphic databases enhances the TLM program by taking full advantages of AM/FM/GIS capabilities. The program provides a general system information inspection function as well as a load analysis and inquiry function which allow engineers to examine in detail the distribution system facilities or to perceive the loading conditions of a specified distribution device. In addition, the program provides a load distribution map overview function for easily investigating a feeder-wide load distribution through a full-color graphic screen. This application program can be applied to keep the distribution transformers from being damaged due to overloading or to prevent inefficient operation by reason of very light-loading conditions.","PeriodicalId":383749,"journal":{"name":"Proceedings of the 20th International Conference on Power Industry Computer Applications","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":"{\"title\":\"Design of a TLM application program based on an AM/FM/GIS system\",\"authors\":\"T. Chen, Jeng-Tyan Cherng\",\"doi\":\"10.1109/PICA.1997.599424\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces the design of a transformer load management (TLM) application program based on an automated mapping/facilities management/geographic information system (AM/FM/GIS). The data required for this application is mainly extracted from the databases of the AM/FM/GIS system and customer information system (CIS) and combined with customer daily load patterns obtained by load surveys over a long-term period. This integration environment including graphic and nongraphic databases enhances the TLM program by taking full advantages of AM/FM/GIS capabilities. The program provides a general system information inspection function as well as a load analysis and inquiry function which allow engineers to examine in detail the distribution system facilities or to perceive the loading conditions of a specified distribution device. In addition, the program provides a load distribution map overview function for easily investigating a feeder-wide load distribution through a full-color graphic screen. This application program can be applied to keep the distribution transformers from being damaged due to overloading or to prevent inefficient operation by reason of very light-loading conditions.\",\"PeriodicalId\":383749,\"journal\":{\"name\":\"Proceedings of the 20th International Conference on Power Industry Computer Applications\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 20th International Conference on Power Industry Computer Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PICA.1997.599424\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 20th International Conference on Power Industry Computer Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PICA.1997.599424","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of a TLM application program based on an AM/FM/GIS system
This paper introduces the design of a transformer load management (TLM) application program based on an automated mapping/facilities management/geographic information system (AM/FM/GIS). The data required for this application is mainly extracted from the databases of the AM/FM/GIS system and customer information system (CIS) and combined with customer daily load patterns obtained by load surveys over a long-term period. This integration environment including graphic and nongraphic databases enhances the TLM program by taking full advantages of AM/FM/GIS capabilities. The program provides a general system information inspection function as well as a load analysis and inquiry function which allow engineers to examine in detail the distribution system facilities or to perceive the loading conditions of a specified distribution device. In addition, the program provides a load distribution map overview function for easily investigating a feeder-wide load distribution through a full-color graphic screen. This application program can be applied to keep the distribution transformers from being damaged due to overloading or to prevent inefficient operation by reason of very light-loading conditions.