电手术中轴向体结构中的高频电流分布

S. Selikowitz, J. Lacourse, G. Gerhard
{"title":"电手术中轴向体结构中的高频电流分布","authors":"S. Selikowitz, J. Lacourse, G. Gerhard","doi":"10.1109/NEBC.1988.19360","DOIUrl":null,"url":null,"abstract":"High-frequency current distribution was investigated while performing a simulated electrosurgical procedure (transurethral resection/TUR) in a canine model utilizing a function generator, spectrum analyzer, and current probes to measure current. Contour plots from recordings on integument muscle, nerve, vein, and artery tissue at sequential axial sites revealed current totals of 45% in artery, 24% in vein, 13% both in skin and muscle, and 5% in nerve. The investigations reveal that, during endoscopic (TUR) and other electrosurgical procedures, anatomic structures such as great vessels may act as preferential high-frequency current conduits and could potentially facilitate serious sequelae, such as obturator nerve-muscle spasm, electrical burns, or even cardiac arrythmias (at higher power levels).<<ETX>>","PeriodicalId":165980,"journal":{"name":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"High frequency current distribution in axial body structures during electrosurgery\",\"authors\":\"S. Selikowitz, J. Lacourse, G. Gerhard\",\"doi\":\"10.1109/NEBC.1988.19360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High-frequency current distribution was investigated while performing a simulated electrosurgical procedure (transurethral resection/TUR) in a canine model utilizing a function generator, spectrum analyzer, and current probes to measure current. Contour plots from recordings on integument muscle, nerve, vein, and artery tissue at sequential axial sites revealed current totals of 45% in artery, 24% in vein, 13% both in skin and muscle, and 5% in nerve. The investigations reveal that, during endoscopic (TUR) and other electrosurgical procedures, anatomic structures such as great vessels may act as preferential high-frequency current conduits and could potentially facilitate serious sequelae, such as obturator nerve-muscle spasm, electrical burns, or even cardiac arrythmias (at higher power levels).<<ETX>>\",\"PeriodicalId\":165980,\"journal\":{\"name\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1988.19360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1988.19360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

利用函数发生器、频谱分析仪和电流探头测量电流,在犬模型中进行模拟电外科手术(经尿道电切/TUR)时,研究了高频电流分布。从连续轴位的被膜肌、神经、静脉和动脉组织记录的等高线图显示,目前动脉组织占45%,静脉组织占24%,皮肤和肌肉组织占13%,神经组织占5%。研究表明,在内窥镜(TUR)和其他电外科手术过程中,解剖结构(如大血管)可能作为优先的高频电流导管,并可能促进严重的后遗症,如闭孔神经肌肉痉挛、电烧伤,甚至心律失常(在更高的功率水平下)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High frequency current distribution in axial body structures during electrosurgery
High-frequency current distribution was investigated while performing a simulated electrosurgical procedure (transurethral resection/TUR) in a canine model utilizing a function generator, spectrum analyzer, and current probes to measure current. Contour plots from recordings on integument muscle, nerve, vein, and artery tissue at sequential axial sites revealed current totals of 45% in artery, 24% in vein, 13% both in skin and muscle, and 5% in nerve. The investigations reveal that, during endoscopic (TUR) and other electrosurgical procedures, anatomic structures such as great vessels may act as preferential high-frequency current conduits and could potentially facilitate serious sequelae, such as obturator nerve-muscle spasm, electrical burns, or even cardiac arrythmias (at higher power levels).<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信