带主动前端变换器的磁场定向控制五相电机驱动器分析

A. Iqbal, S. Payami, R. Behera, A. Abdallah, H. Abu-Rub
{"title":"带主动前端变换器的磁场定向控制五相电机驱动器分析","authors":"A. Iqbal, S. Payami, R. Behera, A. Abdallah, H. Abu-Rub","doi":"10.1109/PECON.2012.6450245","DOIUrl":null,"url":null,"abstract":"The paper presents field oriented control of a five-phase induction motor drive system. The five-phase induction motor is supplied from a current controlled five-phase voltage source inverter and the inverter is supplied from a three-phase active front end converter. The novelty of the paper lies in the development of the five-phase drive with the active front converter. The front end converter has two control loops, the dc link voltage control and the source side current control with unity power factor operation. Simple hysteresis controllers are used to control the input from the source and output to the load currents (five-phase induction motor stator current). The validity of the control is validated using analytical, simulation and experimental approaches.","PeriodicalId":135966,"journal":{"name":"2012 IEEE International Conference on Power and Energy (PECon)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of a field oriented controlled five-phase motor drive with active front end converter\",\"authors\":\"A. Iqbal, S. Payami, R. Behera, A. Abdallah, H. Abu-Rub\",\"doi\":\"10.1109/PECON.2012.6450245\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents field oriented control of a five-phase induction motor drive system. The five-phase induction motor is supplied from a current controlled five-phase voltage source inverter and the inverter is supplied from a three-phase active front end converter. The novelty of the paper lies in the development of the five-phase drive with the active front converter. The front end converter has two control loops, the dc link voltage control and the source side current control with unity power factor operation. Simple hysteresis controllers are used to control the input from the source and output to the load currents (five-phase induction motor stator current). The validity of the control is validated using analytical, simulation and experimental approaches.\",\"PeriodicalId\":135966,\"journal\":{\"name\":\"2012 IEEE International Conference on Power and Energy (PECon)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Power and Energy (PECon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2012.6450245\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2012.6450245","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文介绍了一种五相感应电动机驱动系统的磁场定向控制。五相感应电动机由电流控制的五相电压源逆变器提供,逆变器由三相有源前端转换器提供。本文的新颖之处在于开发了带有源前置变换器的五相驱动系统。前端变换器有直流环节电压控制和源侧电流控制两个控制回路,采用统一功率因数运行。简单的磁滞控制器用于控制从源输入和输出到负载电流(五相感应电动机定子电流)。通过分析、仿真和实验验证了控制的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of a field oriented controlled five-phase motor drive with active front end converter
The paper presents field oriented control of a five-phase induction motor drive system. The five-phase induction motor is supplied from a current controlled five-phase voltage source inverter and the inverter is supplied from a three-phase active front end converter. The novelty of the paper lies in the development of the five-phase drive with the active front converter. The front end converter has two control loops, the dc link voltage control and the source side current control with unity power factor operation. Simple hysteresis controllers are used to control the input from the source and output to the load currents (five-phase induction motor stator current). The validity of the control is validated using analytical, simulation and experimental approaches.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信