{"title":"测试K型温镜循环修改修改器Jofra","authors":"Chandra Dharsni","doi":"10.22202/jrfes.2019.v6i2.3571","DOIUrl":null,"url":null,"abstract":"Thermocouple sensor loop test is performed to ensure the good condition of the sensor. For this reason, a thermocouple sensor loop test is performed using Jofra calibrator to avoid the sensor failing. Prepared Jofra temperature calibrator, set the temperature at Jofra according to the temperature range to be measured. At the voltage gauge (Fluke) set on the Der.C measure, the measuring probe is connected to the thermocouple in the position between the wires (+ and -) to measure the mV value or the temperature of Der.C. Then the sensor is inserted at the test point or location of the heater on the Jofra calibrator. 5 temperature inputs were carried out on the type K thermocouple loop test. The temperature of the K type thermocouple sensor can be used if the results of all the output temperatures on Jofra do not exceed the 5 ° C fair range, 4 temperature outputs are obtained where the sensitivity exceeds the 5 ° C reasonable limit, so the thermocouple sensor type K tested cannot be reused.","PeriodicalId":189667,"journal":{"name":"Jurnal Riset Fisika Edukasi dan Sains","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Test Loop Termokopel Tipe K Dengan Kalibrator Jofra\",\"authors\":\"Chandra Dharsni\",\"doi\":\"10.22202/jrfes.2019.v6i2.3571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Thermocouple sensor loop test is performed to ensure the good condition of the sensor. For this reason, a thermocouple sensor loop test is performed using Jofra calibrator to avoid the sensor failing. Prepared Jofra temperature calibrator, set the temperature at Jofra according to the temperature range to be measured. At the voltage gauge (Fluke) set on the Der.C measure, the measuring probe is connected to the thermocouple in the position between the wires (+ and -) to measure the mV value or the temperature of Der.C. Then the sensor is inserted at the test point or location of the heater on the Jofra calibrator. 5 temperature inputs were carried out on the type K thermocouple loop test. The temperature of the K type thermocouple sensor can be used if the results of all the output temperatures on Jofra do not exceed the 5 ° C fair range, 4 temperature outputs are obtained where the sensitivity exceeds the 5 ° C reasonable limit, so the thermocouple sensor type K tested cannot be reused.\",\"PeriodicalId\":189667,\"journal\":{\"name\":\"Jurnal Riset Fisika Edukasi dan Sains\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Riset Fisika Edukasi dan Sains\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22202/jrfes.2019.v6i2.3571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Riset Fisika Edukasi dan Sains","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22202/jrfes.2019.v6i2.3571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

进行热电偶传感器回路测试,确保传感器状态良好。出于这个原因,使用Jofra校准器执行热电偶传感器环路测试,以避免传感器故障。准备好Jofra温度校准器,根据需要测量的温度范围在Jofra设置温度。在设置在Der.C测量上的电压计(Fluke)上,测量探头连接到导线(+和-)之间的热电偶上,测量mV值或Der.C的温度。然后将传感器插入Jofra校准器上加热器的测试点或位置。在K型热电偶回路试验中进行了5次温度输入。如果Jofra上所有输出温度的结果不超过5°C的公平范围,则K型热电偶传感器的温度可以使用,灵敏度超过5°C合理极限的情况下获得4个温度输出,因此测试的K型热电偶传感器不能重复使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Test Loop Termokopel Tipe K Dengan Kalibrator Jofra
Thermocouple sensor loop test is performed to ensure the good condition of the sensor. For this reason, a thermocouple sensor loop test is performed using Jofra calibrator to avoid the sensor failing. Prepared Jofra temperature calibrator, set the temperature at Jofra according to the temperature range to be measured. At the voltage gauge (Fluke) set on the Der.C measure, the measuring probe is connected to the thermocouple in the position between the wires (+ and -) to measure the mV value or the temperature of Der.C. Then the sensor is inserted at the test point or location of the heater on the Jofra calibrator. 5 temperature inputs were carried out on the type K thermocouple loop test. The temperature of the K type thermocouple sensor can be used if the results of all the output temperatures on Jofra do not exceed the 5 ° C fair range, 4 temperature outputs are obtained where the sensitivity exceeds the 5 ° C reasonable limit, so the thermocouple sensor type K tested cannot be reused.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信