G. Georgiev, S. Ivanov, V. Kozhuharov, M. Mitev, R. Simeonov, L. Tsankov
{"title":"PADME带电粒子探测系统的前端电子性能","authors":"G. Georgiev, S. Ivanov, V. Kozhuharov, M. Mitev, R. Simeonov, L. Tsankov","doi":"10.1109/ET.2018.8549581","DOIUrl":null,"url":null,"abstract":"The PADME charged particle detector system should detect positrons and electrons with efficiency better than 99 {\\%} and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing to perform qualitative check of the produced frontend electronics has been developed and was used to test a total of 256 channels. The obtained time resolution was found to be consistent with the requirements and better than 500 ps for all the channels.","PeriodicalId":374877,"journal":{"name":"2018 IEEE XXVII International Scientific Conference Electronics - ET","volume":"146 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance of the Front-End Electronics of the PADME charged particle detector system\",\"authors\":\"G. Georgiev, S. Ivanov, V. Kozhuharov, M. Mitev, R. Simeonov, L. Tsankov\",\"doi\":\"10.1109/ET.2018.8549581\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The PADME charged particle detector system should detect positrons and electrons with efficiency better than 99 {\\\\%} and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing to perform qualitative check of the produced frontend electronics has been developed and was used to test a total of 256 channels. The obtained time resolution was found to be consistent with the requirements and better than 500 ps for all the channels.\",\"PeriodicalId\":374877,\"journal\":{\"name\":\"2018 IEEE XXVII International Scientific Conference Electronics - ET\",\"volume\":\"146 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE XXVII International Scientific Conference Electronics - ET\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ET.2018.8549581\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE XXVII International Scientific Conference Electronics - ET","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ET.2018.8549581","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance of the Front-End Electronics of the PADME charged particle detector system
The PADME charged particle detector system should detect positrons and electrons with efficiency better than 99 {\%} and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing to perform qualitative check of the produced frontend electronics has been developed and was used to test a total of 256 channels. The obtained time resolution was found to be consistent with the requirements and better than 500 ps for all the channels.