封堵器对三尖瓣的撞击

Z. Khajali, M. Khayatzadeh
{"title":"封堵器对三尖瓣的撞击","authors":"Z. Khajali, M. Khayatzadeh","doi":"10.5812/ACVI.17231","DOIUrl":null,"url":null,"abstract":"3. Comment The most common adverse events after VSD device closure is conduction anomalies (15%) (1, 2). Tricuspid regurgitation is a major consideration in transcatheter closure of VSD (< 2%). The impingement of the occluder on the valve leaflets by interfering with chordae tendineae may cause instant tricuspid regurgitation. Consequently echocardiography and angiography are crucial for confirming the correct deployment of the device (2).","PeriodicalId":429543,"journal":{"name":"Archives of Cardiovascular Imaging","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impingement of the occluder on tricuspid valve\",\"authors\":\"Z. Khajali, M. Khayatzadeh\",\"doi\":\"10.5812/ACVI.17231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"3. Comment The most common adverse events after VSD device closure is conduction anomalies (15%) (1, 2). Tricuspid regurgitation is a major consideration in transcatheter closure of VSD (< 2%). The impingement of the occluder on the valve leaflets by interfering with chordae tendineae may cause instant tricuspid regurgitation. Consequently echocardiography and angiography are crucial for confirming the correct deployment of the device (2).\",\"PeriodicalId\":429543,\"journal\":{\"name\":\"Archives of Cardiovascular Imaging\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Cardiovascular Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5812/ACVI.17231\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Cardiovascular Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/ACVI.17231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

3.VSD关闭后最常见的不良事件是传导异常(15%)(1,2)。三尖瓣反流是经导管关闭VSD的主要考虑因素(< 2%)。封堵器干扰腱索对瓣叶的冲击可引起瞬时三尖瓣反流。因此,超声心动图和血管造影对于确认设备的正确部署至关重要(2)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impingement of the occluder on tricuspid valve
3. Comment The most common adverse events after VSD device closure is conduction anomalies (15%) (1, 2). Tricuspid regurgitation is a major consideration in transcatheter closure of VSD (< 2%). The impingement of the occluder on the valve leaflets by interfering with chordae tendineae may cause instant tricuspid regurgitation. Consequently echocardiography and angiography are crucial for confirming the correct deployment of the device (2).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信