{"title":"采用无源滤波器并联无源滤波器对非线性负载进行电压谐波抑制","authors":"Rajeshwari, A. Bagwari","doi":"10.1109/CSNT.2017.8418524","DOIUrl":null,"url":null,"abstract":"We know that the rise of harmonics is a major problem now days in non-linear loads. The universal use of non-linear loads like in power electronics equipment which amplified the harmonic-related difficulties in service and trade power systems this make an essential requirement of filter. The nonlinear loads be compensated & sometime we can identified but sometimes they include their own non characteristic harmonic portion & not ideal as it is actual in input & voltage sag occur so many times in a day. As increasing the harmonic magnitude component contribution of key problem also rises in industrial sector, so this is a very complex in power system, to overcome we using different methods to reduce this major problem. This paper is presents a proposed model of passive Alter & combination of shunt active & passive filter to reducing harmonic limits in single-phase system as tracked by IEEE std. 519-1992.","PeriodicalId":382417,"journal":{"name":"2017 7th International Conference on Communication Systems and Network Technologies (CSNT)","volume":"211 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"35","resultStr":"{\"title\":\"Voltage harmonic reduction using passive filter shunt passive-active filters for non-linear load\",\"authors\":\"Rajeshwari, A. Bagwari\",\"doi\":\"10.1109/CSNT.2017.8418524\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We know that the rise of harmonics is a major problem now days in non-linear loads. The universal use of non-linear loads like in power electronics equipment which amplified the harmonic-related difficulties in service and trade power systems this make an essential requirement of filter. The nonlinear loads be compensated & sometime we can identified but sometimes they include their own non characteristic harmonic portion & not ideal as it is actual in input & voltage sag occur so many times in a day. As increasing the harmonic magnitude component contribution of key problem also rises in industrial sector, so this is a very complex in power system, to overcome we using different methods to reduce this major problem. This paper is presents a proposed model of passive Alter & combination of shunt active & passive filter to reducing harmonic limits in single-phase system as tracked by IEEE std. 519-1992.\",\"PeriodicalId\":382417,\"journal\":{\"name\":\"2017 7th International Conference on Communication Systems and Network Technologies (CSNT)\",\"volume\":\"211 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"35\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 7th International Conference on Communication Systems and Network Technologies (CSNT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CSNT.2017.8418524\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 7th International Conference on Communication Systems and Network Technologies (CSNT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CSNT.2017.8418524","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage harmonic reduction using passive filter shunt passive-active filters for non-linear load
We know that the rise of harmonics is a major problem now days in non-linear loads. The universal use of non-linear loads like in power electronics equipment which amplified the harmonic-related difficulties in service and trade power systems this make an essential requirement of filter. The nonlinear loads be compensated & sometime we can identified but sometimes they include their own non characteristic harmonic portion & not ideal as it is actual in input & voltage sag occur so many times in a day. As increasing the harmonic magnitude component contribution of key problem also rises in industrial sector, so this is a very complex in power system, to overcome we using different methods to reduce this major problem. This paper is presents a proposed model of passive Alter & combination of shunt active & passive filter to reducing harmonic limits in single-phase system as tracked by IEEE std. 519-1992.