{"title":"低压电弧电极间电场的研究:理论模型的实验验证","authors":"D. Podolsky, V. Kapustin, V. Metscheraykov","doi":"10.1109/HOLM.1999.795933","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is both the experimental verification of the theoretical model of electric field in arc presence and developing a new circuit breaker design approach. The experimental idea was based on numerical calculation. It consists of measurement of back strike probability for two dummy embodiments. The calculation has shown that the back strike must take place in the first embodiment, but the back strike probability is zero in the second embodiment. The experimental measurements confirm the numerical calculation results fully.","PeriodicalId":299141,"journal":{"name":"Electrical Contacts - 1999. Proceedings of the Forty-Fifth IEEE Holm Conference on Electrical Contacts (Cat. No.99CB36343)","volume":"801 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Study of electric field between two electrodes with arc at a low voltage: The experimental verification of the theoretical model\",\"authors\":\"D. Podolsky, V. Kapustin, V. Metscheraykov\",\"doi\":\"10.1109/HOLM.1999.795933\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this paper is both the experimental verification of the theoretical model of electric field in arc presence and developing a new circuit breaker design approach. The experimental idea was based on numerical calculation. It consists of measurement of back strike probability for two dummy embodiments. The calculation has shown that the back strike must take place in the first embodiment, but the back strike probability is zero in the second embodiment. The experimental measurements confirm the numerical calculation results fully.\",\"PeriodicalId\":299141,\"journal\":{\"name\":\"Electrical Contacts - 1999. Proceedings of the Forty-Fifth IEEE Holm Conference on Electrical Contacts (Cat. No.99CB36343)\",\"volume\":\"801 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Contacts - 1999. Proceedings of the Forty-Fifth IEEE Holm Conference on Electrical Contacts (Cat. No.99CB36343)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.1999.795933\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Contacts - 1999. Proceedings of the Forty-Fifth IEEE Holm Conference on Electrical Contacts (Cat. No.99CB36343)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.1999.795933","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study of electric field between two electrodes with arc at a low voltage: The experimental verification of the theoretical model
The purpose of this paper is both the experimental verification of the theoretical model of electric field in arc presence and developing a new circuit breaker design approach. The experimental idea was based on numerical calculation. It consists of measurement of back strike probability for two dummy embodiments. The calculation has shown that the back strike must take place in the first embodiment, but the back strike probability is zero in the second embodiment. The experimental measurements confirm the numerical calculation results fully.