基于噪声适应的直流母线电流检测的PWM脉冲修改新方法

Yoichiro Arakawa, S. Aoyagi, K. Nagata, Yusuke Arao
{"title":"基于噪声适应的直流母线电流检测的PWM脉冲修改新方法","authors":"Yoichiro Arakawa, S. Aoyagi, K. Nagata, Yusuke Arao","doi":"10.1109/IPEC.2010.5543327","DOIUrl":null,"url":null,"abstract":"Methods to detect DC bus current in order to reconstruct three-phase currents have a well-known problem of short DC pulse duration. To expand the pulse duration, several pulse width modulation (PWM) modification techniques have been proposed. The \"Half Pulse Shift (HPS) method is very promising because it has both robustness against detection errors that occur due to current ripple and low acoustic noise. In general, a common-mode noise current permeates the DC bus current and causes detection errors, so the duration of a pulse expanded by PWM modification method is longer than the decay time of the common-mode noise. This decay time is dependent on the electrical environment, especially power supply cable from the inverter to the motor. Although the pulse duration to avoid common-mode noise can be estimated, another problem may arise; the pulse duration may be limited by the controllable range of the output voltage. We propose a new PWM modification method to ease the limit of the pulse duration. Numerical analysis confirmed that this method can expand the operation area in which current is detectable. Experimental results indicated that the proposed method offers stable operation and robustness against noise caused by the electrical environment.","PeriodicalId":353540,"journal":{"name":"The 2010 International Power Electronics Conference - ECCE ASIA -","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A new PWM pulse modification procedure of DC bus current detection for noise adaptation\",\"authors\":\"Yoichiro Arakawa, S. Aoyagi, K. Nagata, Yusuke Arao\",\"doi\":\"10.1109/IPEC.2010.5543327\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Methods to detect DC bus current in order to reconstruct three-phase currents have a well-known problem of short DC pulse duration. To expand the pulse duration, several pulse width modulation (PWM) modification techniques have been proposed. The \\\"Half Pulse Shift (HPS) method is very promising because it has both robustness against detection errors that occur due to current ripple and low acoustic noise. In general, a common-mode noise current permeates the DC bus current and causes detection errors, so the duration of a pulse expanded by PWM modification method is longer than the decay time of the common-mode noise. This decay time is dependent on the electrical environment, especially power supply cable from the inverter to the motor. Although the pulse duration to avoid common-mode noise can be estimated, another problem may arise; the pulse duration may be limited by the controllable range of the output voltage. We propose a new PWM modification method to ease the limit of the pulse duration. Numerical analysis confirmed that this method can expand the operation area in which current is detectable. Experimental results indicated that the proposed method offers stable operation and robustness against noise caused by the electrical environment.\",\"PeriodicalId\":353540,\"journal\":{\"name\":\"The 2010 International Power Electronics Conference - ECCE ASIA -\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 2010 International Power Electronics Conference - ECCE ASIA -\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2010.5543327\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 2010 International Power Electronics Conference - ECCE ASIA -","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2010.5543327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

检测直流母线电流以重建三相电流的方法有一个众所周知的问题,即直流脉冲持续时间短。为了扩大脉冲持续时间,提出了几种脉宽调制(PWM)修改技术。“半脉冲移位”(HPS)方法非常有前途,因为它对由电流纹波和低噪声引起的检测误差具有鲁棒性。一般情况下,共模噪声电流会渗透到直流母线电流中,导致检测误差,因此通过PWM修改方法扩展的脉冲持续时间要长于共模噪声的衰减时间。这种衰减时间取决于电气环境,特别是从逆变器到电机的供电电缆。虽然可以估计避免共模噪声的脉冲持续时间,但可能会出现另一个问题;脉冲持续时间可能受到输出电压可控范围的限制。我们提出了一种新的PWM修改方法来缓解脉冲持续时间的限制。数值分析表明,该方法可以扩大电流检测的操作范围。实验结果表明,该方法运行稳定,对电气环境噪声具有较强的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new PWM pulse modification procedure of DC bus current detection for noise adaptation
Methods to detect DC bus current in order to reconstruct three-phase currents have a well-known problem of short DC pulse duration. To expand the pulse duration, several pulse width modulation (PWM) modification techniques have been proposed. The "Half Pulse Shift (HPS) method is very promising because it has both robustness against detection errors that occur due to current ripple and low acoustic noise. In general, a common-mode noise current permeates the DC bus current and causes detection errors, so the duration of a pulse expanded by PWM modification method is longer than the decay time of the common-mode noise. This decay time is dependent on the electrical environment, especially power supply cable from the inverter to the motor. Although the pulse duration to avoid common-mode noise can be estimated, another problem may arise; the pulse duration may be limited by the controllable range of the output voltage. We propose a new PWM modification method to ease the limit of the pulse duration. Numerical analysis confirmed that this method can expand the operation area in which current is detectable. Experimental results indicated that the proposed method offers stable operation and robustness against noise caused by the electrical environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信