{"title":"铂电阻精密温度计","authors":"Wenna Li, Pan Gong","doi":"10.1109/ICCASE.2011.5997740","DOIUrl":null,"url":null,"abstract":"A design method of high precision Thermometer which is based on AT89C52 was presented in this paper. To improve system accuracy, dual current source bridge and linear interpolation algorithm were used. And a new test way which is combined hardware and software method was proposed.","PeriodicalId":369749,"journal":{"name":"2011 International Conference on Control, Automation and Systems Engineering (CASE)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Platinum Resistance Precision Thermometer\",\"authors\":\"Wenna Li, Pan Gong\",\"doi\":\"10.1109/ICCASE.2011.5997740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A design method of high precision Thermometer which is based on AT89C52 was presented in this paper. To improve system accuracy, dual current source bridge and linear interpolation algorithm were used. And a new test way which is combined hardware and software method was proposed.\",\"PeriodicalId\":369749,\"journal\":{\"name\":\"2011 International Conference on Control, Automation and Systems Engineering (CASE)\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Control, Automation and Systems Engineering (CASE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCASE.2011.5997740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Control, Automation and Systems Engineering (CASE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCASE.2011.5997740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A design method of high precision Thermometer which is based on AT89C52 was presented in this paper. To improve system accuracy, dual current source bridge and linear interpolation algorithm were used. And a new test way which is combined hardware and software method was proposed.