控制下心血管缺氧反应的MATLAB建模

Kinana Rashwani, Omran Saad, Fatima Al Zahraa Zaarour, Mohamad HajjHassan, Mohamad Abou Ali, L. Hamawy, A. Kassem
{"title":"控制下心血管缺氧反应的MATLAB建模","authors":"Kinana Rashwani, Omran Saad, Fatima Al Zahraa Zaarour, Mohamad HajjHassan, Mohamad Abou Ali, L. Hamawy, A. Kassem","doi":"10.1109/ICABME53305.2021.9604829","DOIUrl":null,"url":null,"abstract":"Ursino is one of the exceptional authors and researchers who described distinct regulatory mechanisms which control the haemodynamic variables during hypoxia. Obstacles we faced with Ursino are several incomplete implementations of mathematical models, which necessitate combining more than one of his researches. Combining partitions of such researches using different software (MATLAB/SIMULINK) other than what Ursino did use (SIMNON), grant the lead to more polished performance. SIMULINK software is much faster, easier to use, outputs more accurate and fine-tuned signals, with the ability to analyze any output at real-time simulation. Moreover, the implementation of Ursino’s work lacks controlling the overall system, which can be settled using Model Predictive Controller (MPC). This latter is a Multi-Input/Multi-Output (MIMO) controller that carries several outputs of the implemented model and referenced data, giving birth to numerous signals as stimuli for plant-parts of the system. Results show how MPC controller is ruling the thresholds of the sympathetic efferent activities to the heart and vessels, driving them to regulate arterial pressure of oxygen (PaO2) in blood to its initial normal range.","PeriodicalId":294393,"journal":{"name":"2021 Sixth International Conference on Advances in Biomedical Engineering (ICABME)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"MATLAB Modeling of Cardiovascular Response to Hypoxia with Control\",\"authors\":\"Kinana Rashwani, Omran Saad, Fatima Al Zahraa Zaarour, Mohamad HajjHassan, Mohamad Abou Ali, L. Hamawy, A. Kassem\",\"doi\":\"10.1109/ICABME53305.2021.9604829\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ursino is one of the exceptional authors and researchers who described distinct regulatory mechanisms which control the haemodynamic variables during hypoxia. Obstacles we faced with Ursino are several incomplete implementations of mathematical models, which necessitate combining more than one of his researches. Combining partitions of such researches using different software (MATLAB/SIMULINK) other than what Ursino did use (SIMNON), grant the lead to more polished performance. SIMULINK software is much faster, easier to use, outputs more accurate and fine-tuned signals, with the ability to analyze any output at real-time simulation. Moreover, the implementation of Ursino’s work lacks controlling the overall system, which can be settled using Model Predictive Controller (MPC). This latter is a Multi-Input/Multi-Output (MIMO) controller that carries several outputs of the implemented model and referenced data, giving birth to numerous signals as stimuli for plant-parts of the system. Results show how MPC controller is ruling the thresholds of the sympathetic efferent activities to the heart and vessels, driving them to regulate arterial pressure of oxygen (PaO2) in blood to its initial normal range.\",\"PeriodicalId\":294393,\"journal\":{\"name\":\"2021 Sixth International Conference on Advances in Biomedical Engineering (ICABME)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Sixth International Conference on Advances in Biomedical Engineering (ICABME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICABME53305.2021.9604829\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Sixth International Conference on Advances in Biomedical Engineering (ICABME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICABME53305.2021.9604829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

乌尔西诺是杰出的作者和研究人员之一,他描述了缺氧时控制血流动力学变量的独特调节机制。我们面临的障碍是几个数学模型的不完整实现,这需要将他的多个研究结合起来。结合使用不同软件(MATLAB/SIMULINK)而不是Ursino使用的软件(SIMNON)进行这些研究的分区,使lead的性能更加完善。SIMULINK软件更快,更易于使用,输出更准确和微调的信号,具有分析实时模拟的任何输出的能力。此外,Ursino的工作在实施中缺乏对整个系统的控制,这可以使用模型预测控制器(MPC)来解决。后者是一个多输入/多输出(MIMO)控制器,它携带实现模型和参考数据的几个输出,产生许多信号作为系统的植物部分的刺激。结果显示MPC控制器是如何控制心脏和血管的交感神经传出活动的阈值,驱动它们将血液中的动脉压(PaO2)调节到其初始正常范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
MATLAB Modeling of Cardiovascular Response to Hypoxia with Control
Ursino is one of the exceptional authors and researchers who described distinct regulatory mechanisms which control the haemodynamic variables during hypoxia. Obstacles we faced with Ursino are several incomplete implementations of mathematical models, which necessitate combining more than one of his researches. Combining partitions of such researches using different software (MATLAB/SIMULINK) other than what Ursino did use (SIMNON), grant the lead to more polished performance. SIMULINK software is much faster, easier to use, outputs more accurate and fine-tuned signals, with the ability to analyze any output at real-time simulation. Moreover, the implementation of Ursino’s work lacks controlling the overall system, which can be settled using Model Predictive Controller (MPC). This latter is a Multi-Input/Multi-Output (MIMO) controller that carries several outputs of the implemented model and referenced data, giving birth to numerous signals as stimuli for plant-parts of the system. Results show how MPC controller is ruling the thresholds of the sympathetic efferent activities to the heart and vessels, driving them to regulate arterial pressure of oxygen (PaO2) in blood to its initial normal range.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信