电站大型电机局部放电的在线测量

I. Culbert, H. Dhirani, B. Gupta
{"title":"电站大型电机局部放电的在线测量","authors":"I. Culbert, H. Dhirani, B. Gupta","doi":"10.1109/EEIC.2001.965754","DOIUrl":null,"url":null,"abstract":"For several decades, off-line and/or on-line partial discharge (PD) measurements have been used for condition assessment of stator insulation systems in motors and generators. Many large critical motors in fossil and nuclear generating stations have surge capacitors installed on their phase terminals. On-line PD measurements on eight such motors were done without contact with high voltage terminals in Ontario Power Generation (OPG, earlier Ontario Hydro) by installing high (or radio) frequency current transformers (HFCT or RFCT) and line frequency current transformers (LFCT) on the grounding leads of the surge capacitors. The PD and line frequency voltage signals were picked from the HFCT and the LFCT, respectively. Passive filters were used to eliminate interference from high magnitude pulses generated by exciters in the generating station. A commercial instrument analyzed the PD pulses in terms of magnitude and relationship to the phase of the line voltage. Measurements have been repeated several times. This paper presents the the results obtained so far. Separate off-line tests on a similar motor showed that the HFCT method is at least as sensitive as the conventional OPG method, which uses a capacitive coupler, a wide-band filter, and an oscilloscope.","PeriodicalId":228071,"journal":{"name":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"On-line measurement of partial discharges on large motors in a generating station\",\"authors\":\"I. Culbert, H. Dhirani, B. Gupta\",\"doi\":\"10.1109/EEIC.2001.965754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For several decades, off-line and/or on-line partial discharge (PD) measurements have been used for condition assessment of stator insulation systems in motors and generators. Many large critical motors in fossil and nuclear generating stations have surge capacitors installed on their phase terminals. On-line PD measurements on eight such motors were done without contact with high voltage terminals in Ontario Power Generation (OPG, earlier Ontario Hydro) by installing high (or radio) frequency current transformers (HFCT or RFCT) and line frequency current transformers (LFCT) on the grounding leads of the surge capacitors. The PD and line frequency voltage signals were picked from the HFCT and the LFCT, respectively. Passive filters were used to eliminate interference from high magnitude pulses generated by exciters in the generating station. A commercial instrument analyzed the PD pulses in terms of magnitude and relationship to the phase of the line voltage. Measurements have been repeated several times. This paper presents the the results obtained so far. Separate off-line tests on a similar motor showed that the HFCT method is at least as sensitive as the conventional OPG method, which uses a capacitive coupler, a wide-band filter, and an oscilloscope.\",\"PeriodicalId\":228071,\"journal\":{\"name\":\"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEIC.2001.965754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2001.965754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

几十年来,离线和/或在线局部放电(PD)测量已被用于电机和发电机定子绝缘系统的状态评估。在化石燃料和核能发电站中,许多大型关键电机的相端都安装了浪涌电容器。通过在浪涌电容器的接地引线上安装高频(或射频)电流互感器(HFCT或RFCT)和线频电流互感器(LFCT),在没有接触安大略省发电公司(OPG,早期的安大略省水力发电公司)高压端子的情况下,对8台这样的电机进行了在线PD测量。分别从HFCT和LFCT中提取PD和线频电压信号。无源滤波器用于消除电站励磁器产生的高量级脉冲的干扰。商用仪器分析了PD脉冲的幅度和与线路电压相位的关系。测量已经重复了好几次。本文介绍了目前所取得的结果。在类似电机上进行的单独离线测试表明,HFCT方法至少与使用电容耦合器、宽带滤波器和示波器的传统OPG方法一样灵敏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On-line measurement of partial discharges on large motors in a generating station
For several decades, off-line and/or on-line partial discharge (PD) measurements have been used for condition assessment of stator insulation systems in motors and generators. Many large critical motors in fossil and nuclear generating stations have surge capacitors installed on their phase terminals. On-line PD measurements on eight such motors were done without contact with high voltage terminals in Ontario Power Generation (OPG, earlier Ontario Hydro) by installing high (or radio) frequency current transformers (HFCT or RFCT) and line frequency current transformers (LFCT) on the grounding leads of the surge capacitors. The PD and line frequency voltage signals were picked from the HFCT and the LFCT, respectively. Passive filters were used to eliminate interference from high magnitude pulses generated by exciters in the generating station. A commercial instrument analyzed the PD pulses in terms of magnitude and relationship to the phase of the line voltage. Measurements have been repeated several times. This paper presents the the results obtained so far. Separate off-line tests on a similar motor showed that the HFCT method is at least as sensitive as the conventional OPG method, which uses a capacitive coupler, a wide-band filter, and an oscilloscope.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信