单、串并联MPPT充电控制器性能分析

Zubair Mehmood, Y. Bilal, Muniba Bashir, A. Asghar
{"title":"单、串并联MPPT充电控制器性能分析","authors":"Zubair Mehmood, Y. Bilal, Muniba Bashir, A. Asghar","doi":"10.1109/INTELSE.2016.7475134","DOIUrl":null,"url":null,"abstract":"Maximum Power Point Tracking (MPPT) charge controller is used as an intermediate device in solar system between photovoltaic (PV) panels and batteries. Multiple panels are usually used to meet higher energy demands in large solar PV systems by connecting them in series/parallel configurations. This piece of work is based on performance analysis of MPPT charge controller with series and parallel connections of solar PV panels. The effect of each configuration is analyzed using software and hardware setup. Reason for varying output behavior of MPPT with different connecting schemes of PV panels is discussed. The combined results of electrical tacker (MPPT) and mechanical sun tracker are also presented in this paper for both of above said configurations.","PeriodicalId":127671,"journal":{"name":"2016 International Conference on Intelligent Systems Engineering (ICISE)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Performance analysis of MPPT charge controller with single and series/parallel connected PV panels\",\"authors\":\"Zubair Mehmood, Y. Bilal, Muniba Bashir, A. Asghar\",\"doi\":\"10.1109/INTELSE.2016.7475134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Maximum Power Point Tracking (MPPT) charge controller is used as an intermediate device in solar system between photovoltaic (PV) panels and batteries. Multiple panels are usually used to meet higher energy demands in large solar PV systems by connecting them in series/parallel configurations. This piece of work is based on performance analysis of MPPT charge controller with series and parallel connections of solar PV panels. The effect of each configuration is analyzed using software and hardware setup. Reason for varying output behavior of MPPT with different connecting schemes of PV panels is discussed. The combined results of electrical tacker (MPPT) and mechanical sun tracker are also presented in this paper for both of above said configurations.\",\"PeriodicalId\":127671,\"journal\":{\"name\":\"2016 International Conference on Intelligent Systems Engineering (ICISE)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Intelligent Systems Engineering (ICISE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTELSE.2016.7475134\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Intelligent Systems Engineering (ICISE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTELSE.2016.7475134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

最大功率点跟踪(MPPT)充电控制器是太阳能系统中光伏板与电池之间的中间器件。在大型太阳能光伏系统中,为了满足更高的能源需求,通常采用多板串联/并联的方式。这项工作是基于对太阳能光伏板串联和并联的MPPT充电控制器的性能分析。通过软件和硬件设置分析了每种配置的效果。讨论了不同光伏板连接方式下MPPT输出性能变化的原因。文中还介绍了两种配置下的电动粘接器(MPPT)和机械式太阳跟踪器的组合结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance analysis of MPPT charge controller with single and series/parallel connected PV panels
Maximum Power Point Tracking (MPPT) charge controller is used as an intermediate device in solar system between photovoltaic (PV) panels and batteries. Multiple panels are usually used to meet higher energy demands in large solar PV systems by connecting them in series/parallel configurations. This piece of work is based on performance analysis of MPPT charge controller with series and parallel connections of solar PV panels. The effect of each configuration is analyzed using software and hardware setup. Reason for varying output behavior of MPPT with different connecting schemes of PV panels is discussed. The combined results of electrical tacker (MPPT) and mechanical sun tracker are also presented in this paper for both of above said configurations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信