{"title":"用于胆固醇检测的传统无结场效应晶体管","authors":"Md. Abdul Barik, M. Sarma, J. C. Dutta","doi":"10.1109/EDCAV.2015.7060545","DOIUrl":null,"url":null,"abstract":"The present study compares the traditional field effect transistors with newly developed junctionless carbon nanotube field effect transistor (JLCNTFET) for cholesterol detection. JLCNTFET has been fabricated using electrochemical deposition (ECD) technique on indium tin oxide (ITO) coated glass. A digital multimeter (DMM) has been used for measurement of cholesterol response in a glass pot containing phosphate buffer saline (PBS). The response study implies that JLCNTFET shows improved sensitivity than other for cholesterol detection. From this work, it has been observed that fabrication of junctionless CNTFET is simpler and requires minimal instrument. Therefore, effort has been made to utilize this nano-structured JLCNTFET for estimation of various clinical disorders.","PeriodicalId":277103,"journal":{"name":"2015 International Conference on Electronic Design, Computer Networks & Automated Verification (EDCAV)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Traditional and junctionless field effect transistor for cholesterol detection\",\"authors\":\"Md. Abdul Barik, M. Sarma, J. C. Dutta\",\"doi\":\"10.1109/EDCAV.2015.7060545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study compares the traditional field effect transistors with newly developed junctionless carbon nanotube field effect transistor (JLCNTFET) for cholesterol detection. JLCNTFET has been fabricated using electrochemical deposition (ECD) technique on indium tin oxide (ITO) coated glass. A digital multimeter (DMM) has been used for measurement of cholesterol response in a glass pot containing phosphate buffer saline (PBS). The response study implies that JLCNTFET shows improved sensitivity than other for cholesterol detection. From this work, it has been observed that fabrication of junctionless CNTFET is simpler and requires minimal instrument. Therefore, effort has been made to utilize this nano-structured JLCNTFET for estimation of various clinical disorders.\",\"PeriodicalId\":277103,\"journal\":{\"name\":\"2015 International Conference on Electronic Design, Computer Networks & Automated Verification (EDCAV)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Electronic Design, Computer Networks & Automated Verification (EDCAV)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDCAV.2015.7060545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Electronic Design, Computer Networks & Automated Verification (EDCAV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDCAV.2015.7060545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

将传统场效应晶体管与新开发的无结碳纳米管场效应晶体管(JLCNTFET)用于胆固醇检测进行了比较。采用电化学沉积(ECD)技术在氧化铟锡(ITO)镀膜玻璃上制备了JLCNTFET。用数字万用表(DMM)测量含磷酸盐缓冲盐水(PBS)的玻璃罐中的胆固醇反应。反应研究表明,JLCNTFET对胆固醇检测的灵敏度高于其他方法。从这项工作,它已经观察到,制造无结CNTFET是更简单的,需要最少的仪器。因此,人们努力利用这种纳米结构的JLCNTFET来估计各种临床疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Traditional and junctionless field effect transistor for cholesterol detection
The present study compares the traditional field effect transistors with newly developed junctionless carbon nanotube field effect transistor (JLCNTFET) for cholesterol detection. JLCNTFET has been fabricated using electrochemical deposition (ECD) technique on indium tin oxide (ITO) coated glass. A digital multimeter (DMM) has been used for measurement of cholesterol response in a glass pot containing phosphate buffer saline (PBS). The response study implies that JLCNTFET shows improved sensitivity than other for cholesterol detection. From this work, it has been observed that fabrication of junctionless CNTFET is simpler and requires minimal instrument. Therefore, effort has been made to utilize this nano-structured JLCNTFET for estimation of various clinical disorders.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信