{"title":"单相有源滤波器单周期控制的仿真与实验","authors":"Cheng Huaiying, L. Wenjuan, Jiang Bo","doi":"10.1109/MIC.2013.6758135","DOIUrl":null,"url":null,"abstract":"Single-phase shunt active power filter (APF) is able to compensate harmonics in grid. This paper uses PSCAD/EMTDC to build a simulation model of system based on single-phase shunt APF with one-cycle control under bipolar modulation. In the meantime, it simulates compensation performance for system. Single-phase APF is designed and tested on the basis of simulation. The simulation and experimental results show APF has a good application prospect because it can sufficiently compensate for grid, control circuit has simple structure and dynamic characteristic is fine.","PeriodicalId":404630,"journal":{"name":"Proceedings of 2013 2nd International Conference on Measurement, Information and Control","volume":"106 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Simulation and experiment of single-phase APF with one-cycle control\",\"authors\":\"Cheng Huaiying, L. Wenjuan, Jiang Bo\",\"doi\":\"10.1109/MIC.2013.6758135\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Single-phase shunt active power filter (APF) is able to compensate harmonics in grid. This paper uses PSCAD/EMTDC to build a simulation model of system based on single-phase shunt APF with one-cycle control under bipolar modulation. In the meantime, it simulates compensation performance for system. Single-phase APF is designed and tested on the basis of simulation. The simulation and experimental results show APF has a good application prospect because it can sufficiently compensate for grid, control circuit has simple structure and dynamic characteristic is fine.\",\"PeriodicalId\":404630,\"journal\":{\"name\":\"Proceedings of 2013 2nd International Conference on Measurement, Information and Control\",\"volume\":\"106 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 2013 2nd International Conference on Measurement, Information and Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MIC.2013.6758135\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2013 2nd International Conference on Measurement, Information and Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MIC.2013.6758135","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simulation and experiment of single-phase APF with one-cycle control
Single-phase shunt active power filter (APF) is able to compensate harmonics in grid. This paper uses PSCAD/EMTDC to build a simulation model of system based on single-phase shunt APF with one-cycle control under bipolar modulation. In the meantime, it simulates compensation performance for system. Single-phase APF is designed and tested on the basis of simulation. The simulation and experimental results show APF has a good application prospect because it can sufficiently compensate for grid, control circuit has simple structure and dynamic characteristic is fine.