{"title":"电压稳定机设计- powerformer /sup TM/改进的场电流加热控制","authors":"S. Lindahl","doi":"10.1109/PESW.2001.917036","DOIUrl":null,"url":null,"abstract":"The risk for voltage collapse requires that the system operator use available reactive resources in the receiving area to maintain the voltage level. There is hence a need to boost the reactive generation from synchronous machines. ABB has developed a new class of synchronous machines, Powerformer/sup TM/, which are able to deliver electric power directly at transmission voltage levels. The first Powerformer has a rating of 45 kV, 11 MVA and 600 rpm. It has now (October 2000) accumulated more that 10,000 hours of successful operation. Powerformer has a better overload capability than a conventional generator.","PeriodicalId":253534,"journal":{"name":"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Improved control of field current heating for voltage stability machine design-Powerformer/sup TM/\",\"authors\":\"S. Lindahl\",\"doi\":\"10.1109/PESW.2001.917036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The risk for voltage collapse requires that the system operator use available reactive resources in the receiving area to maintain the voltage level. There is hence a need to boost the reactive generation from synchronous machines. ABB has developed a new class of synchronous machines, Powerformer/sup TM/, which are able to deliver electric power directly at transmission voltage levels. The first Powerformer has a rating of 45 kV, 11 MVA and 600 rpm. It has now (October 2000) accumulated more that 10,000 hours of successful operation. Powerformer has a better overload capability than a conventional generator.\",\"PeriodicalId\":253534,\"journal\":{\"name\":\"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESW.2001.917036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2001.917036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improved control of field current heating for voltage stability machine design-Powerformer/sup TM/
The risk for voltage collapse requires that the system operator use available reactive resources in the receiving area to maintain the voltage level. There is hence a need to boost the reactive generation from synchronous machines. ABB has developed a new class of synchronous machines, Powerformer/sup TM/, which are able to deliver electric power directly at transmission voltage levels. The first Powerformer has a rating of 45 kV, 11 MVA and 600 rpm. It has now (October 2000) accumulated more that 10,000 hours of successful operation. Powerformer has a better overload capability than a conventional generator.