B. Bevensee, F. Newcomer, R. Van Berg, H. Williams
{"title":"用于ATLAS跃迁辐射跟踪器的基线恢复放大-整形-鉴别器","authors":"B. Bevensee, F. Newcomer, R. Van Berg, H. Williams","doi":"10.1109/NSSMIC.1995.504243","DOIUrl":null,"url":null,"abstract":"The ASDBLR is a bipolar integrated circuit that provides eight channels of amplifier, shaper, discriminator and baseline restorer on a 6.17 by 4.78 mm silicon substrate. It is designed for use in the straw-based Transition Radiation Tracker (TRT) of the ATLAS detector at the LHC. Competing requirements for short measurement time (/spl ap/8 ns), good double pulse resolution (/spl ap/40 ns), low power (<30 mW/ch), and low operational threshold (/spl ap/1.5 fC) led to the choice of a largely differential circuit which includes detector tail compensation. A capacitively-coupled baseline restorer eliminates effective threshold shifts that would otherwise occur at the high per-wire hit rates (up to 20 MHz). A full-scale dynamic range of 200 fC and two discriminators with separate threshold adjusts allow the ASDBLR to function both as a tracker and a TR photon detector. Selectable ion-tail compensation makes the circuit compatible with both CF4 and Xe-based gases.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":"{\"title\":\"An amplifier-shaper-discriminator with baseline restoration for the ATLAS transition radiation tracker\",\"authors\":\"B. Bevensee, F. Newcomer, R. Van Berg, H. Williams\",\"doi\":\"10.1109/NSSMIC.1995.504243\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ASDBLR is a bipolar integrated circuit that provides eight channels of amplifier, shaper, discriminator and baseline restorer on a 6.17 by 4.78 mm silicon substrate. It is designed for use in the straw-based Transition Radiation Tracker (TRT) of the ATLAS detector at the LHC. Competing requirements for short measurement time (/spl ap/8 ns), good double pulse resolution (/spl ap/40 ns), low power (<30 mW/ch), and low operational threshold (/spl ap/1.5 fC) led to the choice of a largely differential circuit which includes detector tail compensation. A capacitively-coupled baseline restorer eliminates effective threshold shifts that would otherwise occur at the high per-wire hit rates (up to 20 MHz). A full-scale dynamic range of 200 fC and two discriminators with separate threshold adjusts allow the ASDBLR to function both as a tracker and a TR photon detector. Selectable ion-tail compensation makes the circuit compatible with both CF4 and Xe-based gases.\",\"PeriodicalId\":409998,\"journal\":{\"name\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1995.504243\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.504243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An amplifier-shaper-discriminator with baseline restoration for the ATLAS transition radiation tracker
The ASDBLR is a bipolar integrated circuit that provides eight channels of amplifier, shaper, discriminator and baseline restorer on a 6.17 by 4.78 mm silicon substrate. It is designed for use in the straw-based Transition Radiation Tracker (TRT) of the ATLAS detector at the LHC. Competing requirements for short measurement time (/spl ap/8 ns), good double pulse resolution (/spl ap/40 ns), low power (<30 mW/ch), and low operational threshold (/spl ap/1.5 fC) led to the choice of a largely differential circuit which includes detector tail compensation. A capacitively-coupled baseline restorer eliminates effective threshold shifts that would otherwise occur at the high per-wire hit rates (up to 20 MHz). A full-scale dynamic range of 200 fC and two discriminators with separate threshold adjusts allow the ASDBLR to function both as a tracker and a TR photon detector. Selectable ion-tail compensation makes the circuit compatible with both CF4 and Xe-based gases.