{"title":"三城市群气味滋扰监测","authors":"J. Gębicki, T. Dymerski, J. Namieśnik","doi":"10.1117/12.2244679","DOIUrl":null,"url":null,"abstract":"The paper describes a principle of operation of odor nuisance monitoring network, which is being designed in the tri-city agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field olfactometers were used to determine mean concentration of odorants, which amounted from 2.2 to 30.2 ou/m3 depending on the place of measurement. In case of the investigation with the electronic nose prototype a classification of the ambient air samples with respect to the place of sampling was performed utilizing kNN algorithm supported with a cross-validation method. Correct classification of the ambient air samples was at the level of 66.7%. Performed investigation revealed that discrimination of the ambient air samples differing in concentration of odorants and place of origin was possible.","PeriodicalId":101814,"journal":{"name":"Scientific Conference on Optical and Electronic Sensors","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring of odor nuisance in the tri-city agglomeration\",\"authors\":\"J. Gębicki, T. Dymerski, J. Namieśnik\",\"doi\":\"10.1117/12.2244679\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes a principle of operation of odor nuisance monitoring network, which is being designed in the tri-city agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field olfactometers were used to determine mean concentration of odorants, which amounted from 2.2 to 30.2 ou/m3 depending on the place of measurement. In case of the investigation with the electronic nose prototype a classification of the ambient air samples with respect to the place of sampling was performed utilizing kNN algorithm supported with a cross-validation method. Correct classification of the ambient air samples was at the level of 66.7%. Performed investigation revealed that discrimination of the ambient air samples differing in concentration of odorants and place of origin was possible.\",\"PeriodicalId\":101814,\"journal\":{\"name\":\"Scientific Conference on Optical and Electronic Sensors\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scientific Conference on Optical and Electronic Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2244679\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific Conference on Optical and Electronic Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2244679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Monitoring of odor nuisance in the tri-city agglomeration
The paper describes a principle of operation of odor nuisance monitoring network, which is being designed in the tri-city agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field olfactometers were used to determine mean concentration of odorants, which amounted from 2.2 to 30.2 ou/m3 depending on the place of measurement. In case of the investigation with the electronic nose prototype a classification of the ambient air samples with respect to the place of sampling was performed utilizing kNN algorithm supported with a cross-validation method. Correct classification of the ambient air samples was at the level of 66.7%. Performed investigation revealed that discrimination of the ambient air samples differing in concentration of odorants and place of origin was possible.