内窥镜跟踪中体内定位的初步研究

M. Ke, Y. Tseng, Cheng-Wei Chen, M. Ho, Feng Lian, J. Yen, Win-Li Lin, Yung-Yaw Chen
{"title":"内窥镜跟踪中体内定位的初步研究","authors":"M. Ke, Y. Tseng, Cheng-Wei Chen, M. Ho, Feng Lian, J. Yen, Win-Li Lin, Yung-Yaw Chen","doi":"10.1109/CACS.2013.6734120","DOIUrl":null,"url":null,"abstract":"An intracorporeal optical tracking system for minimal invasive (MIS) surgery is proposed. MIS has been widely used in laparoscopic surgery since 1980s. Its advantages include small surgical cuts and short recovery time. However, because of the limited workspace and narrow view, MIS is more complicated and costs more time than open surgery. Therefore, the image-guided system plays an important role to give surgeons a better cognition, especially tracking the tip of the instruments. In this study, we proposed a novel approach which is based on intracorporeal optical tracking by using the optical markers with the endoscope. The approach can effectively immune from electromagnetic interference and achieve high tracking accuracy with average error of 1.1 mm.","PeriodicalId":186492,"journal":{"name":"2013 CACS International Automatic Control Conference (CACS)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Preliminary study of intracorporeal localization for endoscopy tracking\",\"authors\":\"M. Ke, Y. Tseng, Cheng-Wei Chen, M. Ho, Feng Lian, J. Yen, Win-Li Lin, Yung-Yaw Chen\",\"doi\":\"10.1109/CACS.2013.6734120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An intracorporeal optical tracking system for minimal invasive (MIS) surgery is proposed. MIS has been widely used in laparoscopic surgery since 1980s. Its advantages include small surgical cuts and short recovery time. However, because of the limited workspace and narrow view, MIS is more complicated and costs more time than open surgery. Therefore, the image-guided system plays an important role to give surgeons a better cognition, especially tracking the tip of the instruments. In this study, we proposed a novel approach which is based on intracorporeal optical tracking by using the optical markers with the endoscope. The approach can effectively immune from electromagnetic interference and achieve high tracking accuracy with average error of 1.1 mm.\",\"PeriodicalId\":186492,\"journal\":{\"name\":\"2013 CACS International Automatic Control Conference (CACS)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 CACS International Automatic Control Conference (CACS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CACS.2013.6734120\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 CACS International Automatic Control Conference (CACS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CACS.2013.6734120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种用于微创手术的体内光学跟踪系统。自20世纪80年代以来,MIS在腹腔镜手术中得到了广泛的应用。其优点是手术切口小,恢复时间短。然而,由于工作空间有限,视野狭窄,MIS比开放手术更复杂,花费时间更长。因此,图像引导系统对外科医生更好的认知,特别是对器械尖端的跟踪具有重要作用。在这项研究中,我们提出了一种基于内窥镜光学标记的体内光学跟踪的新方法。该方法可以有效地抵抗电磁干扰,实现较高的跟踪精度,平均误差为1.1 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preliminary study of intracorporeal localization for endoscopy tracking
An intracorporeal optical tracking system for minimal invasive (MIS) surgery is proposed. MIS has been widely used in laparoscopic surgery since 1980s. Its advantages include small surgical cuts and short recovery time. However, because of the limited workspace and narrow view, MIS is more complicated and costs more time than open surgery. Therefore, the image-guided system plays an important role to give surgeons a better cognition, especially tracking the tip of the instruments. In this study, we proposed a novel approach which is based on intracorporeal optical tracking by using the optical markers with the endoscope. The approach can effectively immune from electromagnetic interference and achieve high tracking accuracy with average error of 1.1 mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信