{"title":"热电联产厂常用发电机母线配置的保护方案考虑","authors":"R.M. Rifaat","doi":"10.1109/WESCAN.1993.270546","DOIUrl":null,"url":null,"abstract":"The author discusses the applications of protective relaying schemes in modern power cogeneration plants with common generator bus arrangements. Main protection system philosophy and scheme characteristics are considered. Emphasis is given to the attributes of common generator bus configurations. High resistance neutral grounding protection sensitivity and coordinate ability are addressed. Critical considerations are identified to be evaluated in the case of plants connected to multi-tap utility transmission lines.<<ETX>>","PeriodicalId":146674,"journal":{"name":"IEEE WESCANEX 93 Communications, Computers and Power in the Modern Environment - Conference Proceedings","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Protection scheme considerations for common generator bus configurations used in cogeneration plants\",\"authors\":\"R.M. Rifaat\",\"doi\":\"10.1109/WESCAN.1993.270546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The author discusses the applications of protective relaying schemes in modern power cogeneration plants with common generator bus arrangements. Main protection system philosophy and scheme characteristics are considered. Emphasis is given to the attributes of common generator bus configurations. High resistance neutral grounding protection sensitivity and coordinate ability are addressed. Critical considerations are identified to be evaluated in the case of plants connected to multi-tap utility transmission lines.<<ETX>>\",\"PeriodicalId\":146674,\"journal\":{\"name\":\"IEEE WESCANEX 93 Communications, Computers and Power in the Modern Environment - Conference Proceedings\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE WESCANEX 93 Communications, Computers and Power in the Modern Environment - Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WESCAN.1993.270546\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE WESCANEX 93 Communications, Computers and Power in the Modern Environment - Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WESCAN.1993.270546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Protection scheme considerations for common generator bus configurations used in cogeneration plants
The author discusses the applications of protective relaying schemes in modern power cogeneration plants with common generator bus arrangements. Main protection system philosophy and scheme characteristics are considered. Emphasis is given to the attributes of common generator bus configurations. High resistance neutral grounding protection sensitivity and coordinate ability are addressed. Critical considerations are identified to be evaluated in the case of plants connected to multi-tap utility transmission lines.<>