{"title":"基于箝位技术的单级全桥PFC变换器及其启动方案","authors":"Daqing Wang, Tao Meng, H. Ben, Yan Liu","doi":"10.1109/IPEMC.2012.6259110","DOIUrl":null,"url":null,"abstract":"Power factor correctin technique is an effect active to eliminate the harmonic pollution of power system. A single-stage power factor corrector basic on clamptive technique is presented in this paper. PFC and AC/DC power conversion is manipulated in one stage circuit. Due to the adoption of high frequency transformer, the electrical isolation between input and output sides can be realized. The voltage stress of each switch is reduced due to the active clamp circuit. By using soft-switching techniques, the bridge devices and the clamp switch could achieve ZVS (Zero-Voltage-Switching). Because of the characteristic of the structure, there is big current peak in the input inductor when the corrector starting-up. The scheme of soft starting-up is introduced, which made the starting-up process smoothly. Experimental results show that this converter has a good effect.","PeriodicalId":236136,"journal":{"name":"Proceedings of The 7th International Power Electronics and Motion Control Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-stage full-bridge PFC converter basic on clamptive technique and its starting-up scheme\",\"authors\":\"Daqing Wang, Tao Meng, H. Ben, Yan Liu\",\"doi\":\"10.1109/IPEMC.2012.6259110\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power factor correctin technique is an effect active to eliminate the harmonic pollution of power system. A single-stage power factor corrector basic on clamptive technique is presented in this paper. PFC and AC/DC power conversion is manipulated in one stage circuit. Due to the adoption of high frequency transformer, the electrical isolation between input and output sides can be realized. The voltage stress of each switch is reduced due to the active clamp circuit. By using soft-switching techniques, the bridge devices and the clamp switch could achieve ZVS (Zero-Voltage-Switching). Because of the characteristic of the structure, there is big current peak in the input inductor when the corrector starting-up. The scheme of soft starting-up is introduced, which made the starting-up process smoothly. Experimental results show that this converter has a good effect.\",\"PeriodicalId\":236136,\"journal\":{\"name\":\"Proceedings of The 7th International Power Electronics and Motion Control Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of The 7th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2012.6259110\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of The 7th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2012.6259110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single-stage full-bridge PFC converter basic on clamptive technique and its starting-up scheme
Power factor correctin technique is an effect active to eliminate the harmonic pollution of power system. A single-stage power factor corrector basic on clamptive technique is presented in this paper. PFC and AC/DC power conversion is manipulated in one stage circuit. Due to the adoption of high frequency transformer, the electrical isolation between input and output sides can be realized. The voltage stress of each switch is reduced due to the active clamp circuit. By using soft-switching techniques, the bridge devices and the clamp switch could achieve ZVS (Zero-Voltage-Switching). Because of the characteristic of the structure, there is big current peak in the input inductor when the corrector starting-up. The scheme of soft starting-up is introduced, which made the starting-up process smoothly. Experimental results show that this converter has a good effect.