{"title":"对某钢筋混凝土建筑进行了运行模态分析,以评估其改建后的动力变化","authors":"D. Roia, F. Gara, E. Speranza, L. Gioiella, L. Dezi","doi":"10.1109/EESMS.2015.7175863","DOIUrl":null,"url":null,"abstract":"The paper deals with the changes of the modal parameters of a r.c frame building sited in Camerino, Italy. Operational modal analysis were performed before and after the seismic retrofitting of the building achieved with an innovative system that uses external steel towers equipped with dissipative devices. Before retrofitting, ambient vibration tests were carried out with the aim of evaluating the actual linear dynamic behavior of the building including the contribution of non-structural components (e.g. external and internal walls); modal parameters, i.e. natural frequencies and mode shapes determined by means of experimental modal analysis, allowed the calibration of a predictive f.e. model of the building which was crucial for the final design of the retrofitting system. Tests were repeated after the retrofitting works, with the main objective to verify that changes of modal parameters are in agreement with those predicted by the f.e. model. Results and comparisons between the modal parameters obtained before and after the retrofitting works demonstrate that the ambient vibration tests and the data processing techniques used allow the identification of the dynamic behavior of r.c. few-storeys buildings under operating conditions and, then, the identification of dynamic changes due to seismic retrofitting works performed with external steel “dissipative towers”. A model updating procedure is carried out to identify the value of the elastic modulus of the different materials constituting structural and non-structural elements.","PeriodicalId":346259,"journal":{"name":"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Operational modal analysis on a r.c. building for the evaluation of the dynamic changes due to retrofitting\",\"authors\":\"D. Roia, F. Gara, E. Speranza, L. Gioiella, L. Dezi\",\"doi\":\"10.1109/EESMS.2015.7175863\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with the changes of the modal parameters of a r.c frame building sited in Camerino, Italy. Operational modal analysis were performed before and after the seismic retrofitting of the building achieved with an innovative system that uses external steel towers equipped with dissipative devices. Before retrofitting, ambient vibration tests were carried out with the aim of evaluating the actual linear dynamic behavior of the building including the contribution of non-structural components (e.g. external and internal walls); modal parameters, i.e. natural frequencies and mode shapes determined by means of experimental modal analysis, allowed the calibration of a predictive f.e. model of the building which was crucial for the final design of the retrofitting system. Tests were repeated after the retrofitting works, with the main objective to verify that changes of modal parameters are in agreement with those predicted by the f.e. model. Results and comparisons between the modal parameters obtained before and after the retrofitting works demonstrate that the ambient vibration tests and the data processing techniques used allow the identification of the dynamic behavior of r.c. few-storeys buildings under operating conditions and, then, the identification of dynamic changes due to seismic retrofitting works performed with external steel “dissipative towers”. A model updating procedure is carried out to identify the value of the elastic modulus of the different materials constituting structural and non-structural elements.\",\"PeriodicalId\":346259,\"journal\":{\"name\":\"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EESMS.2015.7175863\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EESMS.2015.7175863","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文研究了意大利卡梅里诺某钢筋混凝土框架结构的模态参数变化。在建筑抗震改造前后进行了运行模态分析,采用了一个创新的系统,该系统使用了配备耗散装置的外部钢塔。在进行改造之前,进行了环境振动测试,目的是评估建筑物的实际线性动态性能,包括非结构部件(例如外墙和内墙)的贡献;模态参数,即通过实验模态分析确定的固有频率和模态振型,允许对建筑物的预测f.e.模型进行校准,这对改造系统的最终设计至关重要。在改造工程后,重复进行了试验,主要目的是验证模态参数的变化与fe模型预测的变化一致。加固前后模态参数的比较结果表明,环境振动试验和所采用的数据处理技术可以识别钢筋混凝土低层建筑在运行条件下的动力行为,然后识别由于外部钢“耗散塔”进行地震加固工程而引起的动力变化。通过模型更新程序,确定了构成结构单元和非结构单元的不同材料的弹性模量值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Operational modal analysis on a r.c. building for the evaluation of the dynamic changes due to retrofitting
The paper deals with the changes of the modal parameters of a r.c frame building sited in Camerino, Italy. Operational modal analysis were performed before and after the seismic retrofitting of the building achieved with an innovative system that uses external steel towers equipped with dissipative devices. Before retrofitting, ambient vibration tests were carried out with the aim of evaluating the actual linear dynamic behavior of the building including the contribution of non-structural components (e.g. external and internal walls); modal parameters, i.e. natural frequencies and mode shapes determined by means of experimental modal analysis, allowed the calibration of a predictive f.e. model of the building which was crucial for the final design of the retrofitting system. Tests were repeated after the retrofitting works, with the main objective to verify that changes of modal parameters are in agreement with those predicted by the f.e. model. Results and comparisons between the modal parameters obtained before and after the retrofitting works demonstrate that the ambient vibration tests and the data processing techniques used allow the identification of the dynamic behavior of r.c. few-storeys buildings under operating conditions and, then, the identification of dynamic changes due to seismic retrofitting works performed with external steel “dissipative towers”. A model updating procedure is carried out to identify the value of the elastic modulus of the different materials constituting structural and non-structural elements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信