42只小型犬和8只猫的苏黎世迷你无骨水泥全髋关节置换术:手术技术和结果

VCOT Open Pub Date : 2022-07-04 DOI:10.1055/s-0043-1761600
A. Vezzoni, S. Boano, Alyssa Sacristani, S. Bresina, O. Lanz
{"title":"42只小型犬和8只猫的苏黎世迷你无骨水泥全髋关节置换术:手术技术和结果","authors":"A. Vezzoni, S. Boano, Alyssa Sacristani, S. Bresina, O. Lanz","doi":"10.1055/s-0043-1761600","DOIUrl":null,"url":null,"abstract":"Abstract This report aims to describe implant characteristics and procedure for implantation, and comment on and report the clinical outcomes in small dogs and cats using the new Zurich mini cementless total hip system. This study involved 8 cats and 42 dogs, with 3 cats and 6 dogs having bilateral total hip arthroplasties (THA). The mean body weight for cats was 6.5 kg, and the mean body weight for dogs was 9.2 kg. In the group of THAs in cats, capital physeal fracture was the reason for performing a THA in six cases (60%), hip dysplasia was the underlying reason in four cases (30%) and hip luxation in one case (10%). Among the 48 THAs in dogs, hip dysplasia was the underlying cause for performing THA in 27 cases (56%), avascular necrosis of the femoral head in 12 cases (25%), traumatic luxation with underlying hip dysplasia in 4 cases (8.5%), capital physeal fracture in 4 cases (8.5%), and traumatic femoral head fracture in 1 adult dog (2%). Seven postoperative complications were encountered, and all were solved without the need for explanting the prosthesis, except in one case because of the owner's decision. In conclusion, the Zurich mini cementless total hip system performed well in this study, with most dogs and cats having an excellent outcome and no patient being too small for the available implant sizes.","PeriodicalId":443672,"journal":{"name":"VCOT Open","volume":"06 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Zurich Mini Cementless Total Hip Arthroplasty in 42 Small Breed Dogs and 8 Cats: Surgical Technique and Outcomes\",\"authors\":\"A. Vezzoni, S. Boano, Alyssa Sacristani, S. Bresina, O. Lanz\",\"doi\":\"10.1055/s-0043-1761600\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This report aims to describe implant characteristics and procedure for implantation, and comment on and report the clinical outcomes in small dogs and cats using the new Zurich mini cementless total hip system. This study involved 8 cats and 42 dogs, with 3 cats and 6 dogs having bilateral total hip arthroplasties (THA). The mean body weight for cats was 6.5 kg, and the mean body weight for dogs was 9.2 kg. In the group of THAs in cats, capital physeal fracture was the reason for performing a THA in six cases (60%), hip dysplasia was the underlying reason in four cases (30%) and hip luxation in one case (10%). Among the 48 THAs in dogs, hip dysplasia was the underlying cause for performing THA in 27 cases (56%), avascular necrosis of the femoral head in 12 cases (25%), traumatic luxation with underlying hip dysplasia in 4 cases (8.5%), capital physeal fracture in 4 cases (8.5%), and traumatic femoral head fracture in 1 adult dog (2%). Seven postoperative complications were encountered, and all were solved without the need for explanting the prosthesis, except in one case because of the owner's decision. In conclusion, the Zurich mini cementless total hip system performed well in this study, with most dogs and cats having an excellent outcome and no patient being too small for the available implant sizes.\",\"PeriodicalId\":443672,\"journal\":{\"name\":\"VCOT Open\",\"volume\":\"06 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"VCOT Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1761600\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"VCOT Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1761600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要本报告旨在描述植入物的特征和植入过程,并评论和报告小型犬和猫使用新型苏黎世迷你无骨水泥全髋关节系统的临床结果。本研究涉及8只猫和42只狗,其中3只猫和6只狗接受了双侧全髋关节置换术(THA)。猫的平均体重为6.5 kg,狗的平均体重为9.2 kg。在猫髋关节置换术组中,6例(60%)的主要原因是骨骺骨折,4例(30%)的潜在原因是髋关节发育不良,1例(10%)的髋关节脱位。48例犬行THA的根本原因是髋关节发育不良27例(56%),股骨头缺血性坏死12例(25%),外伤性脱位伴髋关节发育不良4例(8.5%),骨骺骨折4例(8.5%),成年犬外伤性股骨头骨折1例(2%)。术后出现7例并发症,除一例因患者的决定外,其余并发症均无需切除假体即可解决。总之,苏黎世迷你无骨水泥全髋关节系统在本研究中表现良好,大多数狗和猫都有很好的结果,并且没有患者太小而无法使用可用的植入物尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Zurich Mini Cementless Total Hip Arthroplasty in 42 Small Breed Dogs and 8 Cats: Surgical Technique and Outcomes
Abstract This report aims to describe implant characteristics and procedure for implantation, and comment on and report the clinical outcomes in small dogs and cats using the new Zurich mini cementless total hip system. This study involved 8 cats and 42 dogs, with 3 cats and 6 dogs having bilateral total hip arthroplasties (THA). The mean body weight for cats was 6.5 kg, and the mean body weight for dogs was 9.2 kg. In the group of THAs in cats, capital physeal fracture was the reason for performing a THA in six cases (60%), hip dysplasia was the underlying reason in four cases (30%) and hip luxation in one case (10%). Among the 48 THAs in dogs, hip dysplasia was the underlying cause for performing THA in 27 cases (56%), avascular necrosis of the femoral head in 12 cases (25%), traumatic luxation with underlying hip dysplasia in 4 cases (8.5%), capital physeal fracture in 4 cases (8.5%), and traumatic femoral head fracture in 1 adult dog (2%). Seven postoperative complications were encountered, and all were solved without the need for explanting the prosthesis, except in one case because of the owner's decision. In conclusion, the Zurich mini cementless total hip system performed well in this study, with most dogs and cats having an excellent outcome and no patient being too small for the available implant sizes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信