Abdullah Faqihuddin, Hermansyah Hermansyah, Eti Kurniati
{"title":"Tinjauan Campuran Beton Normal dengan Penggunaan Superplasticizer Sebagai Bahan Pengganti Air Sebesar 0%; 0,3%; 0;5% Dan 0,7% Berdasarkan Berat Semen","authors":"Abdullah Faqihuddin, Hermansyah Hermansyah, Eti Kurniati","doi":"10.37253/JCEP.V2I1.4389","DOIUrl":null,"url":null,"abstract":"The use of Superplasticizer as a substitute for water in the concrete mixture can increase fatigue with a level of workability that is easy to work, reduce the amount of water up to 20% and increase the compressive strength value higher than normal concrete. PPC cement contains a pozzolanic substance with a particle size smaller than cement which is able to fill the smallest cavities in the concrete mixture to obtain high tightness and density. The purpose of this study was to determine the ratio of the increase between compressive strength and workability in normal concrete mixtures with the use of superplasticizer as a substitute for water and PPC cement. Calculation procedure for normal concrete mix design based on SNI 03-2843-2000, variation of superplasticizer used to replace water is 0.3%; 0.5% & 0.7% based on the weight of cement, the value of the cement water factor (FAS) is 0.42 and the compressive strength value is 25 MPa. The compressive strength test was carried out at the age of 7 days and 28 days. The results of this study indicate that the use of variations superplasticizer as a substitute for water affects thevalue slump, volume weight and compressive strength value of concrete. Thevalue slump highestat a variation of 0.5% is 17 cm, included in thevalue slump plan. Heavy volume 0.7% maximum variation of 2402.4 kg / m3,entered the category of normal berbebot concrete. The highest compressive strength value at 7 days at a variation of 0.5% was 37.5 MPa with a percentage increase in compressive strength obtained at 17.77%, the compressive strength value reached the compressive strength of the plan. The highest compressive strength value at 28 days at a variation of 0.7% is 43.4 MPa with a percentage increase in compressive strength of 17.81%, the compressive strength value at 28 days is included in the high quality concrete category","PeriodicalId":102190,"journal":{"name":"Journal of Civil Engineering and Planning","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Civil Engineering and Planning","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37253/JCEP.V2I1.4389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在混凝土混合料中使用高效减水剂代替水,可在易工作的和易程度上增加疲劳,减水量可达20%,抗压强度值高于普通混凝土。PPC水泥含有一种比水泥粒径小的火山灰物质,能够填充混凝土混合物中最小的空洞,从而获得高的密闭性和密度。本研究的目的是确定使用高效减水剂代替水和PPC水泥的普通混凝土混合料的抗压强度和和易性之间的增长之比。基于SNI 03-2843-2000的普通混凝土配合比设计计算程序,减水剂替代水的变化量为0.3%;按水泥重量0.5% & 0.7%,水泥水系数(FAS)值为0.42,抗压强度值为25 MPa。分别在7日龄和28日龄进行抗压强度试验。研究结果表明,使用变型减水剂替代水对混凝土坍落度值、体积重和抗压强度值均有影响。值坍落度最大值为0.5%,为17 cm,包含在值坍落度计划中。重体积0.7%最大变化2402.4 kg / m3,进入普通柏柏石混凝土范畴。在变化0.5%的情况下,第7天抗压强度最大值为37.5 MPa,抗压强度增加17.77%,达到方案抗压强度。28天最高抗压强度值为43.4 MPa,变化0.7%,抗压强度增加17.81%,28天抗压强度值属于优质混凝土
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tinjauan Campuran Beton Normal dengan Penggunaan Superplasticizer Sebagai Bahan Pengganti Air Sebesar 0%; 0,3%; 0;5% Dan 0,7% Berdasarkan Berat Semen
The use of Superplasticizer as a substitute for water in the concrete mixture can increase fatigue with a level of workability that is easy to work, reduce the amount of water up to 20% and increase the compressive strength value higher than normal concrete. PPC cement contains a pozzolanic substance with a particle size smaller than cement which is able to fill the smallest cavities in the concrete mixture to obtain high tightness and density. The purpose of this study was to determine the ratio of the increase between compressive strength and workability in normal concrete mixtures with the use of superplasticizer as a substitute for water and PPC cement. Calculation procedure for normal concrete mix design based on SNI 03-2843-2000, variation of superplasticizer used to replace water is 0.3%; 0.5% & 0.7% based on the weight of cement, the value of the cement water factor (FAS) is 0.42 and the compressive strength value is 25 MPa. The compressive strength test was carried out at the age of 7 days and 28 days. The results of this study indicate that the use of variations superplasticizer as a substitute for water affects thevalue slump, volume weight and compressive strength value of concrete. Thevalue slump highestat a variation of 0.5% is 17 cm, included in thevalue slump plan. Heavy volume 0.7% maximum variation of 2402.4 kg / m3,entered the category of normal berbebot concrete. The highest compressive strength value at 7 days at a variation of 0.5% was 37.5 MPa with a percentage increase in compressive strength obtained at 17.77%, the compressive strength value reached the compressive strength of the plan. The highest compressive strength value at 28 days at a variation of 0.7% is 43.4 MPa with a percentage increase in compressive strength of 17.81%, the compressive strength value at 28 days is included in the high quality concrete category
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信