蒙塔泽卡姆63kV变电站发生铁磁共振的概率评估

S. Aref, Alireza Sedighi Anaraki, Davoud Abootorabi Zarchi
{"title":"蒙塔泽卡姆63kV变电站发生铁磁共振的概率评估","authors":"S. Aref, Alireza Sedighi Anaraki, Davoud Abootorabi Zarchi","doi":"10.1109/IPAPS49326.2019.9069385","DOIUrl":null,"url":null,"abstract":"catastrophic circumstances and equipment failures in electrical networks are mostly caused by emerging non-linear phenomena. Resonance and Ferroresonance are those phenomena, which have been investigated since, many years ago. Montazer Qaem 63 kV substation is susceptible to ferroresonance due to existing underground cable network and capacitor bank. Ferroresonance conditions are generally initialized in effect of short circuit, breaker phase failure, transformer energizing, load rejection, accidental or scheduled line disconnection, and over voltage in the network. In this paper by means of PSCAD/EMTDC simulation software, probability of occurrence of ferroresonance is examined in Montazer Qaem substation. Several ferroresonant configurations are considered in the network and results are analyzed. Ferroresonance states are classified in to adequate modes by Ferroresonance detection tool. Finally, some solutions to suppress ferroresonance applicable to substation are recommended.","PeriodicalId":230294,"journal":{"name":"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Probability Evaluation of Occurrence of Ferroresonance in Montazer Qaem 63kV Substation\",\"authors\":\"S. Aref, Alireza Sedighi Anaraki, Davoud Abootorabi Zarchi\",\"doi\":\"10.1109/IPAPS49326.2019.9069385\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"catastrophic circumstances and equipment failures in electrical networks are mostly caused by emerging non-linear phenomena. Resonance and Ferroresonance are those phenomena, which have been investigated since, many years ago. Montazer Qaem 63 kV substation is susceptible to ferroresonance due to existing underground cable network and capacitor bank. Ferroresonance conditions are generally initialized in effect of short circuit, breaker phase failure, transformer energizing, load rejection, accidental or scheduled line disconnection, and over voltage in the network. In this paper by means of PSCAD/EMTDC simulation software, probability of occurrence of ferroresonance is examined in Montazer Qaem substation. Several ferroresonant configurations are considered in the network and results are analyzed. Ferroresonance states are classified in to adequate modes by Ferroresonance detection tool. Finally, some solutions to suppress ferroresonance applicable to substation are recommended.\",\"PeriodicalId\":230294,\"journal\":{\"name\":\"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPAPS49326.2019.9069385\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 14th International Conference on Protection and Automation of Power Systems (IPAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPAPS49326.2019.9069385","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

电网中的灾难性环境和设备故障大多是由新兴的非线性现象引起的。共振和铁共振是这些现象,从许多年前就开始研究了。蒙塔泽卡姆63kv变电站由于存在地下电缆网络和电容器组,易发生铁磁谐振。铁磁谐振条件通常是在短路、断路器断相、变压器通电、负载弃用、意外或计划断线以及电网过电压等情况下初始化的。本文利用PSCAD/EMTDC仿真软件,对蒙塔泽卡姆变电站发生铁磁谐振的概率进行了研究。在网络中考虑了几种铁谐振结构,并对结果进行了分析。利用铁磁共振检测工具将铁磁共振状态划分为适当的模式。最后,提出了一些适用于变电站的抑制铁磁谐振的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Probability Evaluation of Occurrence of Ferroresonance in Montazer Qaem 63kV Substation
catastrophic circumstances and equipment failures in electrical networks are mostly caused by emerging non-linear phenomena. Resonance and Ferroresonance are those phenomena, which have been investigated since, many years ago. Montazer Qaem 63 kV substation is susceptible to ferroresonance due to existing underground cable network and capacitor bank. Ferroresonance conditions are generally initialized in effect of short circuit, breaker phase failure, transformer energizing, load rejection, accidental or scheduled line disconnection, and over voltage in the network. In this paper by means of PSCAD/EMTDC simulation software, probability of occurrence of ferroresonance is examined in Montazer Qaem substation. Several ferroresonant configurations are considered in the network and results are analyzed. Ferroresonance states are classified in to adequate modes by Ferroresonance detection tool. Finally, some solutions to suppress ferroresonance applicable to substation are recommended.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信