利用FOD控制的FACTS装置改善PMSG风力综合系统的暂态稳定性

M. Lekshmi, J. Vishnu
{"title":"利用FOD控制的FACTS装置改善PMSG风力综合系统的暂态稳定性","authors":"M. Lekshmi, J. Vishnu","doi":"10.1109/ICCPCT.2017.8074294","DOIUrl":null,"url":null,"abstract":"Wind energy conversion system (WECS) is an emerging trend in energy sector. It is why because of its advantages like non-polluting nature, high efficiency and low running cost. A direct driven Permanent Magnet Synchronous Generator with a wind turbine yields maximum power from the system over all other type of generators due to its high power density and less losses. But when a fault condition occurs WECS can't have fault ride through capability also causes power quality issues which are adversely affect both transmission and distribution side of the system. This paper deals with the load side fault tolerant condition of a permanent magnet synchronous generator based WECS with FACTS device mainly Static Synchronous Series Compensator (SSSC) and proposes a Frequency Oscillation Damping (FOD) controller for FACTS controller which has the ability to withstand all the fault conditions that are taken into consideration. This paper will look at a FACTS controller able to achieve fault tolerant conditions.","PeriodicalId":208028,"journal":{"name":"2017 International Conference on Circuit ,Power and Computing Technologies (ICCPCT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improvement of transient stability in PMSG based wind integrated system using FOD controlled FACTS device\",\"authors\":\"M. Lekshmi, J. Vishnu\",\"doi\":\"10.1109/ICCPCT.2017.8074294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Wind energy conversion system (WECS) is an emerging trend in energy sector. It is why because of its advantages like non-polluting nature, high efficiency and low running cost. A direct driven Permanent Magnet Synchronous Generator with a wind turbine yields maximum power from the system over all other type of generators due to its high power density and less losses. But when a fault condition occurs WECS can't have fault ride through capability also causes power quality issues which are adversely affect both transmission and distribution side of the system. This paper deals with the load side fault tolerant condition of a permanent magnet synchronous generator based WECS with FACTS device mainly Static Synchronous Series Compensator (SSSC) and proposes a Frequency Oscillation Damping (FOD) controller for FACTS controller which has the ability to withstand all the fault conditions that are taken into consideration. This paper will look at a FACTS controller able to achieve fault tolerant conditions.\",\"PeriodicalId\":208028,\"journal\":{\"name\":\"2017 International Conference on Circuit ,Power and Computing Technologies (ICCPCT)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Circuit ,Power and Computing Technologies (ICCPCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCPCT.2017.8074294\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Circuit ,Power and Computing Technologies (ICCPCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCPCT.2017.8074294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

风能转换系统(WECS)是能源领域的一个新兴趋势。这是因为它具有无污染、效率高、运行成本低等优点。一个直接驱动的永磁同步发电机与风力涡轮机产生最大的功率从系统比所有其他类型的发电机由于其高功率密度和更少的损耗。但是,当发生故障时,由于WECS不具备故障穿越能力,也会导致电能质量问题,对系统的输配电端产生不利影响。本文研究了以静态同步串联补偿器(SSSC)为主的永磁同步发电机WECS的负载侧容错条件,并提出了一种能够承受所考虑的所有故障条件的频率振荡阻尼(FOD)控制器。本文将研究一种能够实现容错条件的FACTS控制器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improvement of transient stability in PMSG based wind integrated system using FOD controlled FACTS device
Wind energy conversion system (WECS) is an emerging trend in energy sector. It is why because of its advantages like non-polluting nature, high efficiency and low running cost. A direct driven Permanent Magnet Synchronous Generator with a wind turbine yields maximum power from the system over all other type of generators due to its high power density and less losses. But when a fault condition occurs WECS can't have fault ride through capability also causes power quality issues which are adversely affect both transmission and distribution side of the system. This paper deals with the load side fault tolerant condition of a permanent magnet synchronous generator based WECS with FACTS device mainly Static Synchronous Series Compensator (SSSC) and proposes a Frequency Oscillation Damping (FOD) controller for FACTS controller which has the ability to withstand all the fault conditions that are taken into consideration. This paper will look at a FACTS controller able to achieve fault tolerant conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信