研究与开发应用的iii型风力发电机基准模型

A. Y. Goharrizi, J. C. Alonso, E. Borisova, F. Mosallat, D. Muthumuni
{"title":"研究与开发应用的iii型风力发电机基准模型","authors":"A. Y. Goharrizi, J. C. Alonso, E. Borisova, F. Mosallat, D. Muthumuni","doi":"10.1109/CCECE.2018.8447781","DOIUrl":null,"url":null,"abstract":"This paper presents average and detailed models for type-III wind turbines that can be utilized by researchers and engineers as a benchmark in their research and studies. Both models are developed in PSCAD/EMTDC and their dynamic behavior and computational time are compared against each other. The comparison is conducted for two different dynamic scenarios, fast transients in an event of a fault and slow wind speed variations. It is shown that the simulation results obtained from the average model are comparable to those of the detailed model in terms of accuracy while the simulation time is approximately 15 times faster. The sub-synchronous impedances of both models are calculated via simulation, and it is shown that impedance of the average model resembles the detailed one. Moreover, aggregation model of wind farms is shown, such that intensive computations can be eluded and simulation time can be saved.","PeriodicalId":181463,"journal":{"name":"2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Benchmark Model of Type-III Wind Turbine for Research and Development Applications\",\"authors\":\"A. Y. Goharrizi, J. C. Alonso, E. Borisova, F. Mosallat, D. Muthumuni\",\"doi\":\"10.1109/CCECE.2018.8447781\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents average and detailed models for type-III wind turbines that can be utilized by researchers and engineers as a benchmark in their research and studies. Both models are developed in PSCAD/EMTDC and their dynamic behavior and computational time are compared against each other. The comparison is conducted for two different dynamic scenarios, fast transients in an event of a fault and slow wind speed variations. It is shown that the simulation results obtained from the average model are comparable to those of the detailed model in terms of accuracy while the simulation time is approximately 15 times faster. The sub-synchronous impedances of both models are calculated via simulation, and it is shown that impedance of the average model resembles the detailed one. Moreover, aggregation model of wind farms is shown, such that intensive computations can be eluded and simulation time can be saved.\",\"PeriodicalId\":181463,\"journal\":{\"name\":\"2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCECE.2018.8447781\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE.2018.8447781","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了iii型风力发电机的平均模型和详细模型,可供研究人员和工程师作为研究和研究的基准。在PSCAD/EMTDC中建立了两种模型,并对其动态性能和计算时间进行了比较。比较了两种不同的动态情况,即故障时的快速瞬变和慢风速变化。结果表明,平均模型的仿真结果与精细模型的仿真结果精度相当,而仿真时间约快15倍。通过仿真计算了两种模型的次同步阻抗,结果表明,平均模型的阻抗与详细模型的阻抗相似。并且给出了风电场的聚集模型,避免了密集的计算,节省了仿真时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Benchmark Model of Type-III Wind Turbine for Research and Development Applications
This paper presents average and detailed models for type-III wind turbines that can be utilized by researchers and engineers as a benchmark in their research and studies. Both models are developed in PSCAD/EMTDC and their dynamic behavior and computational time are compared against each other. The comparison is conducted for two different dynamic scenarios, fast transients in an event of a fault and slow wind speed variations. It is shown that the simulation results obtained from the average model are comparable to those of the detailed model in terms of accuracy while the simulation time is approximately 15 times faster. The sub-synchronous impedances of both models are calculated via simulation, and it is shown that impedance of the average model resembles the detailed one. Moreover, aggregation model of wind farms is shown, such that intensive computations can be eluded and simulation time can be saved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信