能源管理系统中分接开关变压器的建模

K. Imhof, F. Oesch, I. Nordanlycke
{"title":"能源管理系统中分接开关变压器的建模","authors":"K. Imhof, F. Oesch, I. Nordanlycke","doi":"10.1109/PICA.1995.515210","DOIUrl":null,"url":null,"abstract":"Tap-changer transformers are used in a power system to influence the voltage profile as well as the distribution of power flow. The coupling of the two transformers, the main transformer and the tap transformer, establishes a complex power system element. The correct modelling of this device has turned out to be critical for the accurate estimation and calculation of the power system state. This paper introduces an improved model which simulates the behaviour at the different tap positions and loading conditions. The paper focuses on the positive sequence system of a regulated connected group consisting of a 3-winding main transformer and a 2-winding tap-changer transformer. Model verification against test reports and experiences gained from using the new model in an EMS are documented.","PeriodicalId":294493,"journal":{"name":"Proceedings of Power Industry Computer Applications Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Modelling of tap-changer transformers in an energy management system\",\"authors\":\"K. Imhof, F. Oesch, I. Nordanlycke\",\"doi\":\"10.1109/PICA.1995.515210\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tap-changer transformers are used in a power system to influence the voltage profile as well as the distribution of power flow. The coupling of the two transformers, the main transformer and the tap transformer, establishes a complex power system element. The correct modelling of this device has turned out to be critical for the accurate estimation and calculation of the power system state. This paper introduces an improved model which simulates the behaviour at the different tap positions and loading conditions. The paper focuses on the positive sequence system of a regulated connected group consisting of a 3-winding main transformer and a 2-winding tap-changer transformer. Model verification against test reports and experiences gained from using the new model in an EMS are documented.\",\"PeriodicalId\":294493,\"journal\":{\"name\":\"Proceedings of Power Industry Computer Applications Conference\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Power Industry Computer Applications Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PICA.1995.515210\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Power Industry Computer Applications Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PICA.1995.515210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

分接开关变压器在电力系统中用于影响电压分布和潮流分布。主变压器和分接变压器这两个变压器的耦合构成了一个复杂的电力系统元件。该装置的正确建模对于电力系统状态的准确估计和计算至关重要。本文介绍了一种改进的模型,用于模拟不同攻丝位置和加载条件下的性能。本文研究了由3绕组主变压器和2绕组分接变压器组成的稳压接群的正序系统。根据测试报告对模型进行验证,并记录在EMS中使用新模型所获得的经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modelling of tap-changer transformers in an energy management system
Tap-changer transformers are used in a power system to influence the voltage profile as well as the distribution of power flow. The coupling of the two transformers, the main transformer and the tap transformer, establishes a complex power system element. The correct modelling of this device has turned out to be critical for the accurate estimation and calculation of the power system state. This paper introduces an improved model which simulates the behaviour at the different tap positions and loading conditions. The paper focuses on the positive sequence system of a regulated connected group consisting of a 3-winding main transformer and a 2-winding tap-changer transformer. Model verification against test reports and experiences gained from using the new model in an EMS are documented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信