{"title":"电网完全可观测条件下pmu的最优定位","authors":"V. Gomathi, V. Ramachandran","doi":"10.1109/ICEES.2011.5725349","DOIUrl":null,"url":null,"abstract":"Improvements in power system control and protection is achieved by utilizing real time synchronized phasor measurements. The trend in recent years is the steady increase of Phasor Measurement Unit (PMU) installations worldwide for various applications those targeted for State Estimation enhancement. This paper solves the optimal placement of phasor measurement units for complete observability using Integer Linear Programming (ILP) solution methodology. ILP is used to determine the optimal number and location of PMUs needed to make the network completely observable. This method is tested on Thirunelveli network and complete system observability after placing optimum number of PMUs has been verified.","PeriodicalId":156837,"journal":{"name":"2011 1st International Conference on Electrical Energy Systems","volume":"135 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Optimal location of PMUs for complete observability of power system network\",\"authors\":\"V. Gomathi, V. Ramachandran\",\"doi\":\"10.1109/ICEES.2011.5725349\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Improvements in power system control and protection is achieved by utilizing real time synchronized phasor measurements. The trend in recent years is the steady increase of Phasor Measurement Unit (PMU) installations worldwide for various applications those targeted for State Estimation enhancement. This paper solves the optimal placement of phasor measurement units for complete observability using Integer Linear Programming (ILP) solution methodology. ILP is used to determine the optimal number and location of PMUs needed to make the network completely observable. This method is tested on Thirunelveli network and complete system observability after placing optimum number of PMUs has been verified.\",\"PeriodicalId\":156837,\"journal\":{\"name\":\"2011 1st International Conference on Electrical Energy Systems\",\"volume\":\"135 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 1st International Conference on Electrical Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEES.2011.5725349\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 1st International Conference on Electrical Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEES.2011.5725349","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

电力系统控制和保护的改进是利用实时同步相量测量实现的。近年来的趋势是,在世界范围内,针对状态估计增强的各种应用,相量测量单元(PMU)的安装稳步增加。本文利用整数线性规划(ILP)求解方法解决了完全可观测相量测量单元的最优配置问题。ILP用于确定pmu的最佳数量和位置,以使网络完全可观察。该方法在Thirunelveli网络上进行了测试,验证了放置最优pmu数量后系统的完全可观测性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal location of PMUs for complete observability of power system network
Improvements in power system control and protection is achieved by utilizing real time synchronized phasor measurements. The trend in recent years is the steady increase of Phasor Measurement Unit (PMU) installations worldwide for various applications those targeted for State Estimation enhancement. This paper solves the optimal placement of phasor measurement units for complete observability using Integer Linear Programming (ILP) solution methodology. ILP is used to determine the optimal number and location of PMUs needed to make the network completely observable. This method is tested on Thirunelveli network and complete system observability after placing optimum number of PMUs has been verified.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信