基于寿命终止度量确定状态监测应用的传感器精度:电容器案例研究

Sravanthi Srikantam, Ranjith Kumar Sreenilayam Raveendran
{"title":"基于寿命终止度量确定状态监测应用的传感器精度:电容器案例研究","authors":"Sravanthi Srikantam, Ranjith Kumar Sreenilayam Raveendran","doi":"10.1109/catcon52335.2021.9670507","DOIUrl":null,"url":null,"abstract":"Condition monitoring is playing a vital role in providing the information on health status of system. One of the approaches is to use sensors embedded in the system, and the measured data will be utilized for estimation of remaining life using end-of-life based diagnostic algorithms. Currently these sensors are selected based on the detectability of features for diagnostics algorithms, without attention to the diagnostic algorithms outcomes at the system level. Relating the diagnostic algorithm critical-to-quality (CTQ) metrics to system level outcomes for maintenance activities is addressed in this paper with a capacitor bank case study. Comparison of the diagnostic algorithm outcome with the actual scenario is carried out by using a confusion matrix and related with system measures such as no fault found and operational interruption rate. Normal probability density functions (pdf) are plotted for healthy capacitor bank and algorithm estimations for degraded capacitor bank at derived mean and standard deviation. Intersecting area of the actual capacitance pdf with the estimated pdf is calculated based on % degradation at various tolerance levels of capacitance estimation. Finding of this method is that the sensor must measure capacitance with 1 to 2% error tolerance for minimum impact on system level outcomes at all levels of capacitor degradation.","PeriodicalId":162130,"journal":{"name":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determining Sensor Accuracy for Condition Monitoring Applications based on End of Life Metrics: Capacitor Case Study\",\"authors\":\"Sravanthi Srikantam, Ranjith Kumar Sreenilayam Raveendran\",\"doi\":\"10.1109/catcon52335.2021.9670507\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Condition monitoring is playing a vital role in providing the information on health status of system. One of the approaches is to use sensors embedded in the system, and the measured data will be utilized for estimation of remaining life using end-of-life based diagnostic algorithms. Currently these sensors are selected based on the detectability of features for diagnostics algorithms, without attention to the diagnostic algorithms outcomes at the system level. Relating the diagnostic algorithm critical-to-quality (CTQ) metrics to system level outcomes for maintenance activities is addressed in this paper with a capacitor bank case study. Comparison of the diagnostic algorithm outcome with the actual scenario is carried out by using a confusion matrix and related with system measures such as no fault found and operational interruption rate. Normal probability density functions (pdf) are plotted for healthy capacitor bank and algorithm estimations for degraded capacitor bank at derived mean and standard deviation. Intersecting area of the actual capacitance pdf with the estimated pdf is calculated based on % degradation at various tolerance levels of capacitance estimation. Finding of this method is that the sensor must measure capacitance with 1 to 2% error tolerance for minimum impact on system level outcomes at all levels of capacitor degradation.\",\"PeriodicalId\":162130,\"journal\":{\"name\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/catcon52335.2021.9670507\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/catcon52335.2021.9670507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

状态监测在提供系统健康状态信息方面起着至关重要的作用。其中一种方法是使用嵌入在系统中的传感器,测量数据将用于使用基于寿命终止的诊断算法来估计剩余寿命。目前,这些传感器的选择是基于诊断算法的特征可检测性,而不考虑诊断算法在系统层面的结果。将诊断算法关键质量(CTQ)指标与维护活动的系统级结果联系起来,本文通过电容器组案例研究进行了讨论。通过使用混淆矩阵,将诊断算法的结果与实际场景进行比较,并与无故障发现和运行中断率等系统度量相关联。绘制了健康电容器组的正态概率密度函数(pdf),并在导出的平均值和标准差下对退化电容器组进行了算法估计。实际电容pdf与估计pdf的相交面积是基于不同容差水平下电容估计的退化%计算的。该方法的发现是,传感器测量电容必须具有1%到2%的误差容限,以便在所有级别的电容退化时对系统级结果的影响最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determining Sensor Accuracy for Condition Monitoring Applications based on End of Life Metrics: Capacitor Case Study
Condition monitoring is playing a vital role in providing the information on health status of system. One of the approaches is to use sensors embedded in the system, and the measured data will be utilized for estimation of remaining life using end-of-life based diagnostic algorithms. Currently these sensors are selected based on the detectability of features for diagnostics algorithms, without attention to the diagnostic algorithms outcomes at the system level. Relating the diagnostic algorithm critical-to-quality (CTQ) metrics to system level outcomes for maintenance activities is addressed in this paper with a capacitor bank case study. Comparison of the diagnostic algorithm outcome with the actual scenario is carried out by using a confusion matrix and related with system measures such as no fault found and operational interruption rate. Normal probability density functions (pdf) are plotted for healthy capacitor bank and algorithm estimations for degraded capacitor bank at derived mean and standard deviation. Intersecting area of the actual capacitance pdf with the estimated pdf is calculated based on % degradation at various tolerance levels of capacitance estimation. Finding of this method is that the sensor must measure capacitance with 1 to 2% error tolerance for minimum impact on system level outcomes at all levels of capacitor degradation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信