利用相量测量数据估计惯性和负载阻尼常数

A. Darbandsari, A. Maroufkhani, T. Amraee
{"title":"利用相量测量数据估计惯性和负载阻尼常数","authors":"A. Darbandsari, A. Maroufkhani, T. Amraee","doi":"10.1109/SGC.2017.8308889","DOIUrl":null,"url":null,"abstract":"Two very important parameters especially in frequency stability analysis, are inertia constant and equivalent load damping constant of system. Equivalent inertia constant depends on inertia constant of synchronous machines in the grid and load damping factor depends on frequency sensitivity of load, especially induction motors. By appearing wide area monitoring systems (WAMS) based on phasor measurement units, equivalent system frequency response can be obtained with high accuracy. In this paper firstly, the equivalent frequency response is achieved by phasor measurements and then according to the transient and steady state characteristics of the frequency response, the inertia and load damping constants are estimated. The performance of proposed method in estimating the equivalent parameters of the system is investigated under different conditions. The developed method is implemented in IEEE 39-Bus dynamic test grid.","PeriodicalId":346749,"journal":{"name":"2017 Smart Grid Conference (SGC)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The estimation of inertia and load damping constants using phasor measurement data\",\"authors\":\"A. Darbandsari, A. Maroufkhani, T. Amraee\",\"doi\":\"10.1109/SGC.2017.8308889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two very important parameters especially in frequency stability analysis, are inertia constant and equivalent load damping constant of system. Equivalent inertia constant depends on inertia constant of synchronous machines in the grid and load damping factor depends on frequency sensitivity of load, especially induction motors. By appearing wide area monitoring systems (WAMS) based on phasor measurement units, equivalent system frequency response can be obtained with high accuracy. In this paper firstly, the equivalent frequency response is achieved by phasor measurements and then according to the transient and steady state characteristics of the frequency response, the inertia and load damping constants are estimated. The performance of proposed method in estimating the equivalent parameters of the system is investigated under different conditions. The developed method is implemented in IEEE 39-Bus dynamic test grid.\",\"PeriodicalId\":346749,\"journal\":{\"name\":\"2017 Smart Grid Conference (SGC)\",\"volume\":\"58 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Smart Grid Conference (SGC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SGC.2017.8308889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Smart Grid Conference (SGC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SGC.2017.8308889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

系统的惯性常数和等效负载阻尼常数是频率稳定性分析中两个非常重要的参数。等效惯性常数取决于电网中同步电机的惯性常数,负载阻尼系数取决于负载特别是感应电机的频率灵敏度。基于相量测量单元的广域监测系统(WAMS)的出现,可以获得高精度的等效系统频率响应。本文首先通过相量测量得到等效频率响应,然后根据频率响应的瞬态和稳态特性,估计出惯性常数和负载阻尼常数。研究了该方法在不同条件下对系统等效参数的估计性能。该方法已在IEEE 39总线动态测试网格中实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The estimation of inertia and load damping constants using phasor measurement data
Two very important parameters especially in frequency stability analysis, are inertia constant and equivalent load damping constant of system. Equivalent inertia constant depends on inertia constant of synchronous machines in the grid and load damping factor depends on frequency sensitivity of load, especially induction motors. By appearing wide area monitoring systems (WAMS) based on phasor measurement units, equivalent system frequency response can be obtained with high accuracy. In this paper firstly, the equivalent frequency response is achieved by phasor measurements and then according to the transient and steady state characteristics of the frequency response, the inertia and load damping constants are estimated. The performance of proposed method in estimating the equivalent parameters of the system is investigated under different conditions. The developed method is implemented in IEEE 39-Bus dynamic test grid.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信