键合线裂纹光弹性模型的试验几何初步结果

C. Smith, K. Gloss, C. Liu
{"title":"键合线裂纹光弹性模型的试验几何初步结果","authors":"C. Smith, K. Gloss, C. Liu","doi":"10.1115/imece1999-0610","DOIUrl":null,"url":null,"abstract":"\n By interrogating polyurethane specimens containing bondlines with cracks photoelastically, the authors are conducting a study of the effect of fixed ends upon the stress intensity factor (SIF) for double edge cracked specimens for test specimens of relatively short height. Preliminary results suggest that, while the presence of the bondline increases the SIF with increasing crack length, reducing the specimen height will reduce the SIF level for all crack lengths.","PeriodicalId":270413,"journal":{"name":"Recent Advances in Solids and Structures","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Test Geometries for Bondline Cracked Photoelastic Models; Preliminary Results\",\"authors\":\"C. Smith, K. Gloss, C. Liu\",\"doi\":\"10.1115/imece1999-0610\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n By interrogating polyurethane specimens containing bondlines with cracks photoelastically, the authors are conducting a study of the effect of fixed ends upon the stress intensity factor (SIF) for double edge cracked specimens for test specimens of relatively short height. Preliminary results suggest that, while the presence of the bondline increases the SIF with increasing crack length, reducing the specimen height will reduce the SIF level for all crack lengths.\",\"PeriodicalId\":270413,\"journal\":{\"name\":\"Recent Advances in Solids and Structures\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Recent Advances in Solids and Structures\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece1999-0610\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Advances in Solids and Structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece1999-0610","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

通过对含有裂纹结合线的聚氨酯试样进行光弹性分析,作者对相对较短高度的双边缘裂纹试样的固定端对应力强度因子(SIF)的影响进行了研究。初步结果表明,随着裂纹长度的增加,结合线的存在会增加SIF,而降低试件高度会降低所有裂纹长度的SIF水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Test Geometries for Bondline Cracked Photoelastic Models; Preliminary Results
By interrogating polyurethane specimens containing bondlines with cracks photoelastically, the authors are conducting a study of the effect of fixed ends upon the stress intensity factor (SIF) for double edge cracked specimens for test specimens of relatively short height. Preliminary results suggest that, while the presence of the bondline increases the SIF with increasing crack length, reducing the specimen height will reduce the SIF level for all crack lengths.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信