Wenguang Chen, Y. Rao, Chang-Hong Shan, G. Fujita, T. Yasutoshi
{"title":"真空溅射离子发生器电源的设计与实验","authors":"Wenguang Chen, Y. Rao, Chang-Hong Shan, G. Fujita, T. Yasutoshi","doi":"10.1109/PCCON.2007.373078","DOIUrl":null,"url":null,"abstract":"A LCLC series-parallel high-frequency ac/ac resonant inverter configure for ion assistant vacuum-sputtering manufacture film is proposed. The characteristic of the sputtering chamber and a simplified steady-state analysis of the inverter, using complex circuit analysis, are presented. The control implementation circuit block diagram is introduced to the resonant inverter, which can implement the output current regulation and variable frequency operation simultaneity; the system stability benefits from this control method. It is suitable for the characteristic of chamber load, and the switching losses to be lower as much as possible in such large dynamic load. The 15 kW-30A prototype power supply is described, and experimental results are given.","PeriodicalId":325362,"journal":{"name":"2007 Power Conversion Conference - Nagoya","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"The Design and Experiment of Ion Generator Power Supply for Vacuum Sputtering\",\"authors\":\"Wenguang Chen, Y. Rao, Chang-Hong Shan, G. Fujita, T. Yasutoshi\",\"doi\":\"10.1109/PCCON.2007.373078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A LCLC series-parallel high-frequency ac/ac resonant inverter configure for ion assistant vacuum-sputtering manufacture film is proposed. The characteristic of the sputtering chamber and a simplified steady-state analysis of the inverter, using complex circuit analysis, are presented. The control implementation circuit block diagram is introduced to the resonant inverter, which can implement the output current regulation and variable frequency operation simultaneity; the system stability benefits from this control method. It is suitable for the characteristic of chamber load, and the switching losses to be lower as much as possible in such large dynamic load. The 15 kW-30A prototype power supply is described, and experimental results are given.\",\"PeriodicalId\":325362,\"journal\":{\"name\":\"2007 Power Conversion Conference - Nagoya\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Power Conversion Conference - Nagoya\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCCON.2007.373078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Conversion Conference - Nagoya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.2007.373078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Design and Experiment of Ion Generator Power Supply for Vacuum Sputtering
A LCLC series-parallel high-frequency ac/ac resonant inverter configure for ion assistant vacuum-sputtering manufacture film is proposed. The characteristic of the sputtering chamber and a simplified steady-state analysis of the inverter, using complex circuit analysis, are presented. The control implementation circuit block diagram is introduced to the resonant inverter, which can implement the output current regulation and variable frequency operation simultaneity; the system stability benefits from this control method. It is suitable for the characteristic of chamber load, and the switching losses to be lower as much as possible in such large dynamic load. The 15 kW-30A prototype power supply is described, and experimental results are given.