基于PWM电压反馈的单相三电平逆变器改进重复控制

B. Ben, Xiu-Bei Zhang, Zhizhong Kan, Rui Zhang, Chunjiang Zhang
{"title":"基于PWM电压反馈的单相三电平逆变器改进重复控制","authors":"B. Ben, Xiu-Bei Zhang, Zhizhong Kan, Rui Zhang, Chunjiang Zhang","doi":"10.1109/PEAC.2014.7038055","DOIUrl":null,"url":null,"abstract":"The dead-time effect of driving signal and the lagging effect of digital control have serious implications for the static and dynamic performance of the inverter distortion voltage, the paper makes a research on static and dynamic performance of diode clamp three-level single phase inverter. The paper regards dead-time effect and lagging effect as a periodic disturbance and proposes a lagging improved repetitive control to improve the accuracy of output voltage and reduce voltage distortion caused by dead-time effect. The control strategy does not need to detect the polarity of current and it saves current sensors which are used in traditional current closed loop. The paper also studies the design of repetitive control filter and phase lead component, and the method that deduces lead link k value according to differential equations repetitive control system is proposed. Finally, the validity of proposed control strategy has been verified by simulation and experiment.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Improved repetitive control of single-phase three-level inverter based on PWM voltage feedback\",\"authors\":\"B. Ben, Xiu-Bei Zhang, Zhizhong Kan, Rui Zhang, Chunjiang Zhang\",\"doi\":\"10.1109/PEAC.2014.7038055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dead-time effect of driving signal and the lagging effect of digital control have serious implications for the static and dynamic performance of the inverter distortion voltage, the paper makes a research on static and dynamic performance of diode clamp three-level single phase inverter. The paper regards dead-time effect and lagging effect as a periodic disturbance and proposes a lagging improved repetitive control to improve the accuracy of output voltage and reduce voltage distortion caused by dead-time effect. The control strategy does not need to detect the polarity of current and it saves current sensors which are used in traditional current closed loop. The paper also studies the design of repetitive control filter and phase lead component, and the method that deduces lead link k value according to differential equations repetitive control system is proposed. Finally, the validity of proposed control strategy has been verified by simulation and experiment.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7038055\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7038055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

驱动信号的死区效应和数字控制的滞后效应对逆变器畸变电压的静态和动态性能有严重影响,本文对二极管钳位三电平单相逆变器的静态和动态性能进行了研究。本文将死区效应和滞后效应视为周期性扰动,提出了一种改进的滞后重复控制,以提高输出电压的精度,减少死区效应引起的电压畸变。该控制策略不需要检测电流的极性,省去了传统电流闭环中使用的电流传感器。本文还研究了重复控制滤波器和相位引线元件的设计,提出了根据微分方程推导重复控制系统引线环节k值的方法。最后,通过仿真和实验验证了所提控制策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improved repetitive control of single-phase three-level inverter based on PWM voltage feedback
The dead-time effect of driving signal and the lagging effect of digital control have serious implications for the static and dynamic performance of the inverter distortion voltage, the paper makes a research on static and dynamic performance of diode clamp three-level single phase inverter. The paper regards dead-time effect and lagging effect as a periodic disturbance and proposes a lagging improved repetitive control to improve the accuracy of output voltage and reduce voltage distortion caused by dead-time effect. The control strategy does not need to detect the polarity of current and it saves current sensors which are used in traditional current closed loop. The paper also studies the design of repetitive control filter and phase lead component, and the method that deduces lead link k value according to differential equations repetitive control system is proposed. Finally, the validity of proposed control strategy has been verified by simulation and experiment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信