用于纤维质量检测的棉绒样品的垃圾分析仪和起子搅拌机的性能评价

S. V. Ghadge, P. G. Patil, S. K. Shukla, V. G. Arude, A. Bharimalla, C. Sundaramoorthy, P. Deshmukh, P. Mandhyan
{"title":"用于纤维质量检测的棉绒样品的垃圾分析仪和起子搅拌机的性能评价","authors":"S. V. Ghadge, P. G. Patil, S. K. Shukla, V. G. Arude, A. Bharimalla, C. Sundaramoorthy, P. Deshmukh, P. Mandhyan","doi":"10.1109/TIAR.2017.8273721","DOIUrl":null,"url":null,"abstract":"Cotton lint samples drawn from densely packed bales are required to be well opened and cleaned before being used for fibre quality assessment using modern testing equipment. Importance of proper opening of lint samples introduced into the porosity chamber for measurement of fibre fineness (micronaire) is well recognized to ensure not only correct micronaire but also strength values. If lint samples are tested as such without any opening and cleaning, there is every possibility of variations in the micronaire reading from the actual value. In this paper, performance of the two equipments namely trash analyzer and opener blender has been analyzed for opening of cotton lint samples to ensure accurate and precise measurement of fibre fineness using High Volume Instrument. It was observed that while both equipments gave similar quality of opening, the capacity of trash analyzer was nearly double due to its larger size when compared to opener blender.","PeriodicalId":149469,"journal":{"name":"2017 IEEE Technological Innovations in ICT for Agriculture and Rural Development (TIAR)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of trash analyzer and opener blender for opening cotton lint samples used in fibre quality testing\",\"authors\":\"S. V. Ghadge, P. G. Patil, S. K. Shukla, V. G. Arude, A. Bharimalla, C. Sundaramoorthy, P. Deshmukh, P. Mandhyan\",\"doi\":\"10.1109/TIAR.2017.8273721\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cotton lint samples drawn from densely packed bales are required to be well opened and cleaned before being used for fibre quality assessment using modern testing equipment. Importance of proper opening of lint samples introduced into the porosity chamber for measurement of fibre fineness (micronaire) is well recognized to ensure not only correct micronaire but also strength values. If lint samples are tested as such without any opening and cleaning, there is every possibility of variations in the micronaire reading from the actual value. In this paper, performance of the two equipments namely trash analyzer and opener blender has been analyzed for opening of cotton lint samples to ensure accurate and precise measurement of fibre fineness using High Volume Instrument. It was observed that while both equipments gave similar quality of opening, the capacity of trash analyzer was nearly double due to its larger size when compared to opener blender.\",\"PeriodicalId\":149469,\"journal\":{\"name\":\"2017 IEEE Technological Innovations in ICT for Agriculture and Rural Development (TIAR)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Technological Innovations in ICT for Agriculture and Rural Development (TIAR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIAR.2017.8273721\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Technological Innovations in ICT for Agriculture and Rural Development (TIAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIAR.2017.8273721","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在使用现代测试设备进行纤维质量评估之前,从密集包装的包中提取的棉绒样品需要充分打开并清洁。为测量纤维细度(马克隆),将棉绒样品引入孔隙室进行适当的开孔是非常重要的,这不仅可以确保正确的马克隆值,还可以确保正确的强度值。如果棉绒样品在没有任何打开和清洗的情况下进行测试,则马克隆读数与实际值完全有可能发生变化。本文分析了垃圾分析仪和开瓶搅拌机两种设备的性能,以保证高容量仪对棉绒样品开瓶时纤维细度的精确测量。结果表明,虽然两种设备的开孔质量相似,但由于垃圾分析仪的体积比开孔搅拌机大,其容量几乎是开孔搅拌机的两倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance evaluation of trash analyzer and opener blender for opening cotton lint samples used in fibre quality testing
Cotton lint samples drawn from densely packed bales are required to be well opened and cleaned before being used for fibre quality assessment using modern testing equipment. Importance of proper opening of lint samples introduced into the porosity chamber for measurement of fibre fineness (micronaire) is well recognized to ensure not only correct micronaire but also strength values. If lint samples are tested as such without any opening and cleaning, there is every possibility of variations in the micronaire reading from the actual value. In this paper, performance of the two equipments namely trash analyzer and opener blender has been analyzed for opening of cotton lint samples to ensure accurate and precise measurement of fibre fineness using High Volume Instrument. It was observed that while both equipments gave similar quality of opening, the capacity of trash analyzer was nearly double due to its larger size when compared to opener blender.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信