用于测量呼出空气中二氧化碳浓度的模块

J. Puton, T. Palko, A. Knap, K. Jasek, B. Siodlowski
{"title":"用于测量呼出空气中二氧化碳浓度的模块","authors":"J. Puton, T. Palko, A. Knap, K. Jasek, B. Siodlowski","doi":"10.1117/12.517129","DOIUrl":null,"url":null,"abstract":"The objective of this work consists in working out of a detection module for capnography (carbon dioxide concentration measurement in anaesthesiology and intensive care). The principle of operation of the module consists of the NDIR method. The basic assumption for construction of this model was using of directly modulated thermal IR source in it. A few models of IR sources were worked out. Their heaters were made from thick platinum layers and foil. Limits of modulation frequency for IR sources were greater than 30 Hz. The detection module consists of an optical part, analogue electronics and microprocessor system with a suitable program. The time dependent concentration of CO2, end tidal concentration of CO2, mean concentration of N2O and breath frequency are output values of the detection module. Measurements are executed 30 times per second. The accuracy of CO2 concentration measurement equals to 5%.","PeriodicalId":405495,"journal":{"name":"Optoelectronic and Electronic Sensors","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Module for measurement of CO2 concentration in exhaled air\",\"authors\":\"J. Puton, T. Palko, A. Knap, K. Jasek, B. Siodlowski\",\"doi\":\"10.1117/12.517129\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this work consists in working out of a detection module for capnography (carbon dioxide concentration measurement in anaesthesiology and intensive care). The principle of operation of the module consists of the NDIR method. The basic assumption for construction of this model was using of directly modulated thermal IR source in it. A few models of IR sources were worked out. Their heaters were made from thick platinum layers and foil. Limits of modulation frequency for IR sources were greater than 30 Hz. The detection module consists of an optical part, analogue electronics and microprocessor system with a suitable program. The time dependent concentration of CO2, end tidal concentration of CO2, mean concentration of N2O and breath frequency are output values of the detection module. Measurements are executed 30 times per second. The accuracy of CO2 concentration measurement equals to 5%.\",\"PeriodicalId\":405495,\"journal\":{\"name\":\"Optoelectronic and Electronic Sensors\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optoelectronic and Electronic Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.517129\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optoelectronic and Electronic Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.517129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

这项工作的目标是为二氧化碳检测(麻醉和重症监护中的二氧化碳浓度测量)设计一个检测模块。模块的工作原理由NDIR方法组成。建立该模型的基本假设是使用直接调制的红外热源。建立了几种红外源的模型。他们的加热器由厚铂层和箔制成。红外光源的调制频率极限大于30 Hz。该检测模块由光学部分、模拟电子部分和具有适当程序的微处理器系统组成。随时间变化的CO2浓度、末潮CO2浓度、N2O平均浓度和呼吸频率是检测模块的输出值。测量每秒执行30次。CO2浓度测量精度为5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Module for measurement of CO2 concentration in exhaled air
The objective of this work consists in working out of a detection module for capnography (carbon dioxide concentration measurement in anaesthesiology and intensive care). The principle of operation of the module consists of the NDIR method. The basic assumption for construction of this model was using of directly modulated thermal IR source in it. A few models of IR sources were worked out. Their heaters were made from thick platinum layers and foil. Limits of modulation frequency for IR sources were greater than 30 Hz. The detection module consists of an optical part, analogue electronics and microprocessor system with a suitable program. The time dependent concentration of CO2, end tidal concentration of CO2, mean concentration of N2O and breath frequency are output values of the detection module. Measurements are executed 30 times per second. The accuracy of CO2 concentration measurement equals to 5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信