{"title":"用单x线相机三维观察通过不透射线心肌标记物测量局部肥大","authors":"A. Muijtjens, J. Roos, M. V. van Oosterhout, F. Prinzen, M. Egmont-Petersen, T. Arts, R. Reneman","doi":"10.1109/CIC.1997.648012","DOIUrl":null,"url":null,"abstract":"Regional differences in hypertrophy may be measured by comparing the positions of radiopaque myocardial markers at multiple time points. Accurate measurement of volume changes requires 3-D reconstruction of marker positions from stereo pairs of images. Using the periodicity of heart motion quasi stereo pairs can be obtained by using one camera at two viewing positions. For this set-up 3-D reconstruction methods were developed. In computer simulations of markers attached to a beating heart (70 mm diameter) the performance of these methods was evaluated. With 12 markers recorded on standard video (256/spl times/256 pixel), a position noise of 0.5 pixel (s.d), and using only a single frame pair, the reconstruction error was 1.7 mm. Using the marker images in a sequence of 50 frames per view, the error reduced to 0.35 mm. By applying a SVD based noise reduction method the error may further be reduced to 0.17 mm. The obtained accuracy is appropriate for the measurement of volume changes of cardiac muscle which are typical of the order of 10%.","PeriodicalId":228649,"journal":{"name":"Computers in Cardiology 1997","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Measuring regional hypertrophy by radiopaque myocardial markers viewed in 3D with a single X-ray camera\",\"authors\":\"A. Muijtjens, J. Roos, M. V. van Oosterhout, F. Prinzen, M. Egmont-Petersen, T. Arts, R. Reneman\",\"doi\":\"10.1109/CIC.1997.648012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Regional differences in hypertrophy may be measured by comparing the positions of radiopaque myocardial markers at multiple time points. Accurate measurement of volume changes requires 3-D reconstruction of marker positions from stereo pairs of images. Using the periodicity of heart motion quasi stereo pairs can be obtained by using one camera at two viewing positions. For this set-up 3-D reconstruction methods were developed. In computer simulations of markers attached to a beating heart (70 mm diameter) the performance of these methods was evaluated. With 12 markers recorded on standard video (256/spl times/256 pixel), a position noise of 0.5 pixel (s.d), and using only a single frame pair, the reconstruction error was 1.7 mm. Using the marker images in a sequence of 50 frames per view, the error reduced to 0.35 mm. By applying a SVD based noise reduction method the error may further be reduced to 0.17 mm. The obtained accuracy is appropriate for the measurement of volume changes of cardiac muscle which are typical of the order of 10%.\",\"PeriodicalId\":228649,\"journal\":{\"name\":\"Computers in Cardiology 1997\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in Cardiology 1997\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1997.648012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Cardiology 1997","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1997.648012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

通过比较多个时间点不透射线心肌标记物的位置,可以测量肥厚的区域差异。体积变化的精确测量需要从立体图像对中对标记位置进行三维重建。利用心脏运动的周期性,可以在两个观测位置使用一台摄像机获得准立体对。为此,开发了三维重建方法。在连接到跳动的心脏(直径70毫米)的标记物的计算机模拟中,对这些方法的性能进行了评估。在标准视频(256/spl次/256像素)上记录12个标记,位置噪声为0.5像素(s.d),仅使用单帧对,重建误差为1.7 mm。使用每视图50帧序列的标记图像,误差降低到0.35 mm。采用基于奇异值分解的降噪方法,误差进一步减小到0.17 mm。所获得的精度适合于测量心肌体积变化,其典型数量级为10%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measuring regional hypertrophy by radiopaque myocardial markers viewed in 3D with a single X-ray camera
Regional differences in hypertrophy may be measured by comparing the positions of radiopaque myocardial markers at multiple time points. Accurate measurement of volume changes requires 3-D reconstruction of marker positions from stereo pairs of images. Using the periodicity of heart motion quasi stereo pairs can be obtained by using one camera at two viewing positions. For this set-up 3-D reconstruction methods were developed. In computer simulations of markers attached to a beating heart (70 mm diameter) the performance of these methods was evaluated. With 12 markers recorded on standard video (256/spl times/256 pixel), a position noise of 0.5 pixel (s.d), and using only a single frame pair, the reconstruction error was 1.7 mm. Using the marker images in a sequence of 50 frames per view, the error reduced to 0.35 mm. By applying a SVD based noise reduction method the error may further be reduced to 0.17 mm. The obtained accuracy is appropriate for the measurement of volume changes of cardiac muscle which are typical of the order of 10%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信